Deposition of manganese in a drinking water distribution system.
نویسندگان
چکیده
The deposition of manganese in a water distribution system with manganese-related "dirty water" problems was studied over a 1-year period. Four monitoring laboratories with Robbins biofilm sampling devices fitted to the water mains were used to correlate the relationship among manganese deposition, the level of manganese in the water, and the chlorination conditions. Manganese deposition occurred by both chemical and microbial processes. Chemical deposition occurred when Mn(II) not removed during water treatment penetrated the filters and entered the distribution system, where it was oxidized by chlorine and chlorine dioxide used for disinfection. Microbial deposition occurred in areas with insufficient chlorination to control the growth of manganese-depositing biofilm. At 0.05 mg of Mn(II) per liter, the chemical deposition rate was much greater than microbial deposition. Significant deposition occurred at 0.03 mg of manganese per liter, and dirty water complaints were not eliminated until manganese levels were continuously less than 0.02 mg/liter and chlorination levels were greater than 0.2 mg/liter. A guideline level of 0.01 mg of manganese per liter is recommended.
منابع مشابه
بررسی پتانسیل خوردگی و رسوب گذاری آب شرب شبکه توزیع شهر کرمان
Background : Occurrence of corrosion and deposition in drinking water in distribution system can leads to economic and health damages. The aim of this study was to investigate the corrosion and precipitation potential of drinking water in Kerman distribution system. Methods : This cross-sectional study was performed from September to November of 2011. For determining the chemical quality of...
متن کاملDetermination of corrosion and scaling levels of drinking water in distribution system: A study in Sarableh city (Ilam), western of Iran
Introduction: Corrosion and scaling of water in distribution systems in spite of imposing economic and aesthetic problems can lead to adverse effects on consumers' health. The present study was conducted to evaluate the corrosion and scaling of water distribution system of Sarableh city (Ilam, Iran) during summer and winter seasons in 2014. Materials and methods: Totally, 60 samples of wate...
متن کاملEvaluation of trends for iron and manganese concentrations in wells, reservoirs, and water distribution networks, Qom city, Iran
Background: This study aimed to evaluated trends for iron and manganese concentrations in wells, reservoirs, and water distribution networks in Qom city during the summer of 2012. Methods: This was a cross-sectional study. The studied scopes consisted of groundwater (60 wells), reservoirs (10 tanks), and water distribution network (33 points). One sample was taken from each source monthly. Stat...
متن کاملNeurotoxicity of inhaled manganese: public health danger in the shower?
CONTEXT Manganese (Mn) is an essential trace element but is neurotoxic at high doses. Showering with Mn-laden water has never been evaluated as a central nervous system (CNS) delivery vector for Mn, even though intranasally administered Mn in laboratory animals circumvents the blood-brain barrier and passes directly into the brain via olfactory pathways. OBJECTIVE To review the literature on ...
متن کاملDetermination of corrosion and sedimentation potential in drinking water distribution system of khorramabad city by corrosion indices and weight loss method
Pirialam R1, Shams khorramabadi Gh2, Shahmansouri MR3, Farzadkiya M4 1. MSc in Environmental Health, Lorestan University of Medical Sciences, Khorramabad, Iran 2. Assistant Professor, Department of Environmental Health, Faculty of Health, Lorestan University of Medical Sciences, Khorramabad, Iran 3. Associate Professor, Department of Environmental Health, Faculty of Health, Isfahan University o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied and environmental microbiology
دوره 56 3 شماره
صفحات -
تاریخ انتشار 1990