A new self-expanding aortic stent valve with annular fixation: in vitro haemodynamic assessment.
نویسندگان
چکیده
OBJECTIVE Balloon-expandable stent valves require flow reduction during implantation (rapid pacing). The present study was designed to compare a self-expanding stent valve with annular fixation versus a balloon-expandable stent valve. METHODS Implantation of a new self-expanding stent valve with annular fixation (Symetis, Lausanne, Switzerland) was assessed versus balloon-expandable stent valve, in a modified Dynatek Dalta pulse duplicator (sealed port access to the ventricle for transapical route simulation), interfaced with a computer for digital readout, carrying a 25 mm porcine aortic valve. The cardiovascular simulator was programmed to mimic an elderly woman with aortic stenosis: 120/85 mmHg aortic pressure, 60 strokes/min (66.5 ml), 35% systole (2.8 l/min). RESULTS A total of 450 cardiac cycles was analysed. Stepwise expansion of the self-expanding stent valve with annular fixation (balloon-expandable stent valve) resulted in systolic ventricular increase from 120 to 121 mmHg (126 to 830+/-76 mmHg)*, and left ventricular outflow obstruction with mean transvalvular gradient of 11+/-1.5 mmHg (366+/-202 mmHg)*, systolic aortic pressure dropped distal to the valve from 121 to 64.5+/-2 mmHg (123 to 55+/-30 mmHg) N.S., and output collapsed to 1.9+/-0.06 l/min (0.71+/-0.37 l/min* (before complete obstruction)). No valve migration occurred in either group. (*=p<0.05). CONCLUSIONS Implantation of this new self-expanding stent valve with annular fixation has little impact on haemodynamics and has the potential for working heart implantation in vivo. Flow reduction (rapid pacing) is not necessary.
منابع مشابه
Three Different Imaging Modalities of a Patient with the Aortic Coarctation
The patient was a 19 year-old woman with the diagnosis of resistant hypertension, although she was under treatment of three classes of anti-hypertensive drugs (beta blocker, angiotensin receptor blocker, diuretic) for more than one year. In physical examination there was only a significant difference between the systolic blood pressure of upper and lower extremities (200 vs. 120 mmHg), without ...
متن کاملTrans-catheter Bioprosthetic Heart Valve Implantation in Iran (Tehran Heart Centre Experience)
Introduction: With the development of interventional cardiology in the world, in addition to coronary and aortic diseases, the treatment of heart valve diseases through catheters has recently begun. The treatment of aortic stenosis (which was only possible with open surgery and valve replacement) was first performed in the world in 2002 by Alain Cribier in France with catheter insertion of the ...
متن کاملTransarterial aortic valve replacement with a self expanding stent in pigs.
OBJECTIVES To evaluate the feasibility of percutaneous aortic valve replacement without cardiac arrest in animal experiments. METHODS A self expanding nitinol stent, containing pulmonary valves from pigs in its proximal part, was implanted in six pigs (94-118 kg) by means of a 25 French catheter through the left subclavian artery under guidance of fluoroscopy and transoesophageal echocardiogr...
متن کاملPreliminary feasibility and hemodynamic performance of a newly-developed self-expanding bioprosthesis and 16-F delivery system in transcatheter aortic valve implantation in sheep
We sought to evaluate the feasibility and hemodynamic performance of a new self-expanding bioprosthesis and 16-F delivery system in sheep. A 23-mm new self-expanding aortic bioprosthesis was implanted in sheep (n = 10) with a 16-F catheter via the right common carotid artery. Each sheep underwent angiography and coronary angiography before intervention, immediately and 1 h after stent implantat...
متن کاملA Strategy of Underexpansion and Ad Hoc Post-Dilation of Balloon-Expandable Transcatheter Aortic Valves in Patients at Risk of Annular Injury: Favorable Mid-Term Outcomes.
OBJECTIVES The aim of this study was to evaluate a strategy of intentional underexpansion of excessively oversized balloon-expandable transcatheter heart valves (THVs) in terms of clinical outcomes, valve function, and frame durability at 1 year. BACKGROUND Transcatheter aortic valve replacement requires the selection of an optimally sized THV to ensure paravalvular sealing and fixation witho...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
دوره 35 6 شماره
صفحات -
تاریخ انتشار 2009