Myocardial efficiency is an important determinant of functional improvement after aortic valve replacement in aortic valve stenosis patients: a combined PET and CMR study.
نویسندگان
چکیده
AIMS The pathophysiology underlying aortic valve stenosis (AVS)-induced cardiac dysfunction and reduced exercise capacity is unclear. We hypothesize that improvement of myocardial external efficiency (MEE)--the ratio between external work and myocardial oxygen consumption (MVO2)--underlies functional improvement of AVS patients after aortic valve replacement (AVR). Therefore, the aim of this proof-of-concept study was to investigate whether myocardial efficiency is reduced in patients with cardiac hypertrophy caused by AVS and to assess the effect of AVR on myocardial efficiency in relation to exercise capacity. METHODS AND RESULTS Echocardiography, cardiopulmonary exercise test, [(11)C]-acetate positron emission tomography and cardiovascular magnetic resonance imaging were performed in 10 AVS patients prior to (pre-AVR) and 4 months after AVR (post-AVR). Fourteen healthy individuals served as control group. MEE was significantly lower in pre-AVR patients (32 ± 7%) than in controls (49 ± 6%). AVR significantly decreased left ventricle mass and MVO2. Also, external work significantly decreased post-AVR reaching similar values as in controls. AVR significantly improved MEE from 32 ± 7 to 37 ± 5% (P = 0.02). Moreover, significant correlations were present between the AVR-induced increase in MEE and changes in both exercise work (r = 0.74, P = 0.01) and peak VO2 (r = 0.67, P = 0.03). However, four AVS patients did not show improved MEE, which was associated with no or minimal improvement in exercise parameters. CONCLUSION MEE is significantly reduced in patients with AVS-induced hypertrophy. Improved MEE is an important predictor of AVR-induced improvement of exercise capacity in AVS patients. Future investigation is needed to confirm our observations in a large prospective, multicenter clinical trial.
منابع مشابه
Transcatheter Aortic Valve Replacement: A Review Article
Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...
متن کاملعوامل خطر تنگی هموگرافت پولمونر پس ازعمل جراحی Ross
Background: The Ross procedure has been known as a good method for aortic valve replacement. Pulmonary allograft postoperative stenosis subsequent to the Ross procedure has been noted as an important disadvantage of this technique, although risk factors related to this complication are not clearly recognized. In this study we evaluate the risk factors of pulmonary allograft stenosis after Ross ...
متن کاملEarly right ventricular dysfunction after transcatheter aortic valve replacement (TAVI): a prospective cardiac magnetic resonance study of open versus transcatheter aortic valve replacement
Background Recent published literature has validated the use of transcatheter aortic valve implantation (TAVI) in highrisk patients with aortic stenosis. These trials and registries have largely focused on combined morbidity and mortality outcomes with little focus given to impact on early myocardial function. We assessed effects on myocardial function, reversible and irreversible myocardial in...
متن کاملAssessment of myocardial oxygenation in patients with severe aortic stenosis before and after aortic valve replacement: an oxygenation-sensitive CMR study
Background Left ventricular hypertrophy in aortic stenosis (AS) is characterised by reduced myocardial perfusion reserve due to coronary microvascular dysfunction. However, it remains unclear whether the hypoperfusion seen in severe AS leads to myocardial tissue deoxygenation and thus, ischemia during stress. The aim of this study was to assess myocardial oxygenation and perfusion in patients w...
متن کاملPre- and post-contrast T1 mapping for detection of myocardial fibrosis in severe aortic stenosis before and after aortic valve replacement
Background Severe aortic stenosis (AS) leads to diffuse fibrosis in the myocardium, which could cause poor clinical outcome. Cardiovascular Magnetic Resonance (CMR) with recently T1 mapping is a promising technique to identify diffuse myocardial fibrosis. The Objective of the present study was to assess myocardial fibrosis by CMR using T1 mapping in patients with surgical AS and evaluate the ev...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European heart journal cardiovascular Imaging
دوره 16 8 شماره
صفحات -
تاریخ انتشار 2015