Determining the apical terminus of root-end resected teeth using three modern apex locators: a comparative ex vivo study.
نویسندگان
چکیده
AIM To assess ex vivo the accuracy of various electronic apex locators in locating the apical terminus of root-end resected teeth. METHODOLOGY Ninety extracted human posterior teeth (182 root canals) were prepared to a minimum size of 40 and filled with gutta-percha and sealer. After resection of the apical 3 mm of the root, the root canal filling was removed using HERO rotary instruments. The size of the root canal at the apical terminus after removal of the filling ranged from size 50 to 90. The root canal length to the apical terminus was determined using 3 apex locators (Root ZX, Raypex4 and Apex Pointer). A new mounting model that utilized a micrometer was used to perform the measurements and to visually determine the actual position of the apical terminus. The frequency of locating the apical terminus and the corresponding 95% confidence interval (CI) were calculated. Additionally, the coefficient of repeatability of each apex locator and the limits of inter-operator agreement were determined. RESULTS All apex locators showed an acceptable repeatability (0.02-0.03 mm coefficient of repeatability) and narrow limits of inter-operator agreement (+0.07 and -0.07 mm). The accuracy of determining the apical terminus within 1 mm in the root canal was as follows: Root ZX 90% (164/182 root-canals) [95%CI: 86-94%], Raypex4 74% (135/182 root-canals) [95%CI: 68-80%], and Apex Pointer 71% (129/182 root canals) [95%CI: 65-77%]. No over-instrumentation resulted when the Root ZX device was used. In contrast, using the Raypex4 or the Apex Pointer device resulted in over-instrumentation in 8 of 182 root canals (4%). CONCLUSIONS Under the conditions of this study all three apex locators were able to detect the apical terminus of root-end resected teeth with an acceptable range. The Root ZX device was the most accurate without over-instrumentation of the root canals.
منابع مشابه
Evaluation of the accuracy of two apex locators in endodontic treatment and retreatments: an ex vivo study
Introduction: Working length determination is important in successful endodontic treatment and retreatment.This study evaluated the accuracy of two electronic apex locators Root ZX and Raypex®6 (EALs) in determining the electronic working length (EWL) of the root canals in endodontic treatment and retreatment. Materials and Methods: Access cavities were prepared on forty extracted, singl...
متن کاملComparative evaluation of the accuracy of two electronic apex locators in determining the working length in teeth with simulated apical root resorption: An in vitro study
INTRODUCTION Accurate determination of working length (WL) is a critical factor for endodontic success. This is commonly achieved using an apex locator which is influenced by the presence or absence of the apical constriction. Hence, this study was done to compare the accuracy of two generations of apex locators in teeth with simulated apical root resorption. MATERIALS AND METHODS Forty maxil...
متن کاملAccuracy of three electronic apex locators in anterior and posterior teeth: an ex vivo study.
INTRODUCTION The aim of this study was to determine in anterior teeth, bicuspids, and molars (1) the accuracy of 3 different electronic apex locators (EALs) in detecting the apical foramen and (2) the accuracy of digital radiography in determining the working length (WL), compared with visible control under a microscope. METHODS By using radiovideography (RVG), we measured the lengths of 120 ...
متن کاملEx vivo evaluation of the accuracy of two electronic apex locators during root canal length determination in primary teeth.
AIM To evaluate ex vivo the accuracy of two electronic apex locators during root canal length determination in primary incisor and molar teeth with different stages of physiological root resorption. METHODOLOGY One calibrated examiner determined the root canal length in 17 primary incisors and 16 primary molars (total of 57 root canals) with different stages of root resorption based on the ac...
متن کاملIn vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination
In vitro evaluation of the accuracy of two new electronic apex locators in root canal length determination Dr. Hasheminia, S.M.* - Dr. Jafari, N.** *Associate Professor of Endodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ** Dentist. Abstract Background & Aim: Radiography is still the common method of measuring working length in root canal therapy. While, gag refl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International endodontic journal
دوره 38 11 شماره
صفحات -
تاریخ انتشار 2005