An Investigation of Applicability of Transporting Water Mist for Cooling Turbine Vanes
نویسندگان
چکیده
This paper presents a numerical study to investigate the feasibility of transporting mist through the internal cooling channel in high-pressure turbine vanes for film cooling over the vane's surface. The idea of using mist film cooling to enhance conventional air cooling has been proven to be a feasible technique in the laboratory conditions and by computational simulations. However, there is a challenge to this technique to prove that the water mist can survive in the very hot environment inside the gas turbine casings and internal air passages and be delivered to the film injection holes. Both a zero-dimensional mist evaporation analytical model and 3-D computational fluid dynamic (CFD) scheme are employed for analysis. In the CFD simulation, the Lagrangian /Eulerian method is used along with the discrete phase model (DPM) to track the evaporation process of water droplets. The high-pressure water mist is injected into the stream of cooling air extracted from the compressor through the outer gas turbine casing near the vane before it reaches the vane internal cooling cavity. Using the mist equivalent of 10% of the cooling air mass flow rate, the results show that, when the liquid droplets are atomized to 30 μm in diameter initially, the droplets can survive inside the internal cooling passages and be delivered to the film cooling injection hole location with droplets of 20 μm in diameter; and alternatively, an initially 20 μm droplet can be delivered at 12μm in diameter, which is sufficiently large for completing the required external film cooling task.
منابع مشابه
Investigation of Applicability of Using Water Mist for Cooling High-Pressure Turbine Components via Rotor Cavity Feed Channels
Mist cooling has been considered as a potential means to significantly enhance cooling the hot components of a gas turbine. However, it is a great challenge to transport mist to locations where cooling is needed due to the high temperature environment and rotating components in the gas turbines. One plausible way is to transport high-pressure water to the rotor cover-plate cavity via a feed cha...
متن کاملTwo-phase Flow Simulation of Mist Film Cooling with Different Wall Heating Conditions
Effective cooling of gas turbine combustor liners, combustor transition pieces, turbine vanes (nozzles) and blades (buckets) is a critical task to protect these components from the flue gas at extremely high temperature. Air film cooling has been successfully used to cool these hot sections for the last half century. However, the net benefits from the traditional methods seem to be marginally i...
متن کاملComputational Analysis of Surface Curvature Effect on Mist Film Cooling Performance
Air film cooling has been widely employed to cool gas turbine hot components such as combustor liners, combustor transition pieces, turbine vanes and blades. Enhancing air film cooling by injecting mist with tiny water droplets with diameters of 5-10μm has been studied in the past on flat surfaces. This paper focuses on computationally investigating the curvature effect on mist/air film cooling...
متن کاملMist/air Cooling in a Two-Pass Rectangular Rotating Channel with 45-deg Angled Rib Turbulators
Increasing the turbine inlet temperature can increase the gas turbine cycle efficiency. In order to increase the turbine inlet temperature significantly, an advanced cooling system has to be essentially developed. Injection of mist to the coolant fluid is considered a promising technique to protect the hot components such as combustor liners, combustor transition pieces, and turbine vanes and b...
متن کاملCFD Model Validation and Prediction of Mist/Steam Cooling in a 180-Degree Bend Tubes
To achieve higher efficiency target of the advanced turbine systems, the closed-loop steam cooling scheme is employed to cool the airfoil. It is proven from the experimental results at laboratory working conditions that injecting mist into steam can significantly augment the heat transfer in the turbine blades with several fundamental studies. The mist cooling technique has to be tested at gas ...
متن کامل