Using a high-affinity antibody for estradiol, thermodynamic and experimental limitations on detection limits for competitive capillary electrophoretic immunoassays were examined. Theoretical modeling of the dose-response curves for such assays allowed for optimization of experimental conditions. Through the examination of experimental and theoretical results generalizations could be made as to the ability of capillary electrophoretic immunoassays to achieve low detection limits. An experimental detection limit of 310 pM, corresponding to 2100 molecules, was achieved. A minimum theoretical detection limit for the antibody of interest was approximated to be 125-525 pM depending on the standard deviation. An overview of the optimization process is given as well as commentary on theoretical predictions.
منابع مشابه
Cyclodextrine Screening for the Chiral Separation of Carvedilol by Capillary Electrophoresis
Carvedilol is administered as a racemic mixture of the R(+)- and S(-)-enantiomers, although it was demonstrated that the two enantiomers exhibit different pharmacological effects and stereoselective pharmacokinetics. The aim of this study was the evaluation of several native and derivatized cyclodextrines as chiral selectors for the separation of carvedilol enantiomers. Stereoselective interact...
متن کاملCyclodextrine Screening for the Chiral Separation of Carvedilol by Capillary Electrophoresis
Carvedilol is administered as a racemic mixture of the R(+)- and S(-)-enantiomers, although it was demonstrated that the two enantiomers exhibit different pharmacological effects and stereoselective pharmacokinetics. The aim of this study was the evaluation of several native and derivatized cyclodextrines as chiral selectors for the separation of carvedilol enantiomers. Stereoselective interact...
متن کاملCapillary Electrophoresis-Based Immunoassays: Principles &Quantitative Applications
The use of capillary electrophoresis as a tool to conduct immunoassays has been an area of increasing interest over the last decade. This approach combines the efficiency, small sample requirements, and relatively high speed of CE with the selectivity of antibodies as binding agents. This review examines the various assay formats and detection modes that have been reported for these assays, alo...
متن کاملImprovement of Electrophoretic Enantioseparation of Amlodipine by Polybrene
In chiral and non-chiral electrophoretic resolution of basic drugs, adsorption of analytes to negatively charged capillary wall could lead to poor repeatability of migration time and peak area. In addition, chiral resolutions of basic drugs are commonly performed in low pH buffers. Therefore, longer analysis time due to suppression of electroosmotic flow (EOF) is another dilemma. In this wor...
متن کاملChemiluminescence-based detection: principles and analytical applications in flowing streams and in immunoassays.
The present paper provides the principles of chemiluminescence (CL) and its powerful applications in analytical chemistry, mainly in the area of flow injection analysis, column liquid chromatographic and capillary electrophoretic separating systems, and its potential in immunoassays. CL is light produced by a chemical reaction. The most common advantages of chemiluminescent reactions are the re...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Electrophoresis
دوره 22 17 شماره
صفحات -
تاریخ انتشار 2001