Total percutaneous access for endovascular aortic aneurysm repair ("Preclose" technique).

نویسندگان

  • W Anthony Lee
  • Michael P Brown
  • Peter R Nelson
  • Thomas S Huber
چکیده

OBJECTIVE Percutaneous access during endovascular aneurysm repair has been difficult owing to the large size of the delivery catheters. This study reports a single-center experience of totally percutaneous access during endovascular abdominal and thoracic aortic repairs using the Preclose Proglide device (Abbott Vascular, Redwood City, Calif). METHODS Between December 2004 and August 2006, 262 endovascular aortic aneurysm repairs were performed. Percutaneous access was used for the introduction of 12F to 24F sheaths (4.4-mm to 8.6-mm outer diameter). The technique involved deployment of two Proglide devices before insertion of the sheath ("Preclose" technique) with the sutures left extracorporeally for closure after conclusion of the procedure. A prospectively maintained endovascular database and medical records were retrospectively reviewed. Rates of technical success, failure modes, and the overall duration of the endovascular repair compared with a similar cohort using open femoral exposures were examined. RESULTS A total of 559 Proglide devices were used to close 279 femoral arteries, and 175 (63%) required the insertion of 18F to 24F sheaths. There were 16 failures, mainly due to obesity, device malfunction, severe calcific disease, and faulty arterial punctures, for a technical success rate of 94.3%. The success rates for 12F to 16F size sheaths were significantly higher than for the larger 18F to 24F sheaths (99.0% vs 91.4%, P<.01). For both endovascular abdominal (EVAR) and thoracic (TEVAR) aortic repairs, the Preclose technique resulted in shorter overall procedure times compared with a similar cohort in which open femoral exposures were used (EVAR, 115 vs 128 min, P<.001; TEVAR, 80 vs 112, P=.019). Despite this reduction of procedure time, the savings on the cost of operating room time was negated by the cost of the Proglide devices ($295 per device). CONCLUSIONS Percutaneous access for endovascular aortic repair is safe and feasible using the Proglide device. Although the success rates are higher for smaller size sheaths, successful closures may be obtained for up to 24F sheaths. Percutaneous access may result in shorter overall procedure times and potentially lower operating room costs, but this appears to be offset by the cost of the closure devices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Percutaneous repair of abdominal aortic aneurysms using the AneuRx stent graft and the percutaneous vascular surgery device.

Endovascular exclusion of abdominal aortic aneurysms (AAAs) was developed in an effort to treat patients who were at high risk for complications following standard surgical repair. Stent grafts used for endovascular repair of AAAs require the use of large-bore sheaths and surgical exposure of the common femoral arteries (CFAs). To decrease the invasiveness of AAA repair, we attempted to perform...

متن کامل

Total percutaneous endovascular aneurysm repair with the dual 6-F Perclose-AT preclosing technique: a case-control study.

PURPOSE To determine the safety and efficacy of total percutaneous access closure for endovascular aortic aneurysm repair with a suture-mediated preclosing technique. MATERIALS AND METHODS One hundred thirty-two femoral access sites in 70 patients who underwent endovascular aortic aneurysm repair were closed percutaneously with off-label use of two F-6 Perclose AT devices preapplied at a 90 d...

متن کامل

A simple sheath removal after open trans-femoral catheterization procedure: the ZIP technique.

The ZIP technique, a surgical equivalent of the 'Preclose' technique, useful for transcatheter aortic valve implantation or endovascular aortic aneurysm repair is described. While percutaneous closure devices are expensive, need a long learning curve and are associated with primary failure, the ZIP technique is easy and allows a quick, safe and anatomical closure of the artery. This procedure a...

متن کامل

An Aortoenteric Fistula Arising after Endovascular Management of a Mycotic Abdominal Aortic Aneurysm Complicated with a Psoas Abscess

Mycotic aortic aneurysms account for 1–3% of all aortic aneurysms. The management of this disease is controversial. Since open surgical repair is associated with high morbidity and mortality rates, endovascular aneurysm repair is an alternative treatment method with promising early and midterm outcomes, although its long-term durability is unknown.Secondary aortoenteric fistulas may occur iatro...

متن کامل

Local Anesthesia for Percutaneous Thoracic Endovascular Aortic Repair.

BACKGROUND Thoracic endovascular aortic repair (TEVAR) requires large-bore vascular access due to the considerable diameters of the endoprosthesis and delivery device. The preclose technique preceding endograft delivery has opened the door for an evolved access strategy. In addition, treatment under local anesthesia offers the advantage of optimal neuromonitoring. The goal of this study was to ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of vascular surgery

دوره 45 6  شماره 

صفحات  -

تاریخ انتشار 2007