Advanced Prototyping of Variable Impedance Prosthetic Sockets for Trans-tibial Amputees: Polyjet Matrix 3D Printing of Comfortable Prosthetic Sockets Using Digital Anatomical Data
نویسنده
چکیده
This work, supported by the Media Lab Consortium, evaluates the design of a Variable Impedance Prosthetic (VIPr) socket for a transtibial amputee using computer-aided design and manufacturing (CAD/CAM). Compliant features are seamlessly integrated into a 3D printed socket to achieve lower interface peak pressures over bony protuberances by using anthropomorphic data acquired through surface scanning and magnetic resonance imaging techniques. An inverse linear mathematical transformation spatially maps quantitative measurements (bone tissue depth) of the human residual limb to the corresponding socket shape and impedance characteristics. The CAD/CAM VIPr socket is compared to a state-of-the-art prosthetic socket of similar internal geometry and shape, designed by a prosthetist using conventional methods. An active, bilateral transtibial male amputee of weight 70 kg walks on a force plate-loaded 5-meter walkway, at self-selected speeds while synchronized ground reaction forces, motion capture data and socket residual limb interface pressures are measured for the evaluated sockets. We anticipated a decreased average interface pressure (measured using the Teksan F-SocketTM pressure sensors) in the VIPr socket, especially over stiff anatomical landmarks including the fibula head, the tibia, lateral and medial femoral condyles and medial tibial flare. Contact interface pressure recorded during stance of a complete gait cycle indicated a 15% and 17% reduction at toe-off and heel-strike respectively at the fibula head while the subject uses a VIPr socket in comparison to a conventional socket of similar internal shape. A corresponding 7% and 8% reduction in pressure is observed along the tibia. Similar trends of high-pressure reductions are observed during stair ascent trials with the VIPr socket. Thesis Supervisor: Dr Hugh Herr Title: Associate Professor of Media Arts and Sciences, Program in Media Arts and Sciences
منابع مشابه
Clinical Evaluation of Prosthetic Sockets Manufactured By Selective Laser Sintering
A pilot study was undertaken to evaluate the clinical acceptance of prosthetic limb sockets manufactured using solid freeform fabrication (SFF). The fabrication of sockets for amputees is a natural application for SFF. The socket is the part of the prosthetic limb that fits onto the amputee’s residual limb. Each socket is custom manufactured for each individual amputee. Four amputees were succe...
متن کاملA Variable-Impedance Prosthetic Socket for a Transtibial Amputee Designed from Magnetic Resonance Imaging Data
This article evaluates the design of a variable impedance prosthetic (VIPr) socket for a transtibial amputee using computeraided design andmanufacturing (CAD/CAM) processes. Compliant features are seamlessly integrated into a three-dimensional printed socket to achieve lower interface peak pressures over bony protuberances by using biomechanical data acquired through surface scanning and magnet...
متن کاملComputer-aided socket design for trans-femoral amputees.
Computer-aided socket design (CASD) is a technique for the design of prosthetic sockets using the advantageous features of computer graphics and calculation. This paper describes a computer-aided technique used to design sockets for patients with trans-tibial lower limb amputations.
متن کاملEngineering a trans-tibial prosthetic socket for the lower limb amputee.
INTRODUCTION This review addresses the different prosthetic socket designs for trans-tibial amputees, the biomechanics behind the designs and the current state of the field. Of particular focus is the classic patella-tendon bearing (PTB) socket and the more recent sockets manufactured using pressure casting techniques and the theory, biomechanics and clinical implications of the two designs. Me...
متن کاملSand-casting technique for trans-tibial prostheses.
A sand-casting technique for trans-tibial sockets was applied to 28 amputees, and the prosthetic fit observed through transparent check sockets. The results were better than historical reports of fittings with plaster of Paris casting by qualified prosthetists. The fit was consistently and evenly larger than the stump, but total contact could be achieved by applying three (two to five) stump so...