Two-peak approximation in kinetic capillary electrophoresis.

نویسندگان

  • Leonid T Cherney
  • Sergey N Krylov
چکیده

Kinetic capillary electrophoresis (KCE) constitutes a toolset of homogeneous kinetic affinity methods for measuring rate constants of formation (k(+)) and dissociation (k(-)) of non-covalent biomolecular complexes, C, formed from two binding partners, A and B. A parameter-based approach of extracting k(+) and k(-) from KCE electropherograms relies on a small number of experimental parameters found from the electropherograms and used in explicit expressions for k(+) and k(-) derived from approximate solutions to mass transfer equations. Deriving the explicit expressions for k(+) and k(-) is challenging but it is justified as the parameter-based approach is the simplest way of finding k(+) and k(-) from KCE electropherograms. Here, we introduce a unique approximate analytical solution of mass transfer equations in KCE termed a "two-peak approximation" and a corresponding parameter-based method for finding k(+) and k(-). The two-peak approximation is applicable to any KCE method in which: (i) A* binds B to form C* (the asterisk denotes a detectable label on A), (ii) two peaks can be identified in a KCE electropherogram and (iii) the concentration of B remains constant. The last condition holds if B is present in access to A* and C* throughout the capillary. In the two-peak approximation, the labeling of A serves only for detection of A and C and, therefore, is not required if A (and thus C) can be observed with a label-free detection technique. We studied the proposed two-peak approximation, in particular, its accuracy, by using the simulated propagation patterns built with the earlier-developed exact solution of the mass-transfer equations for A* and C*. Our results prove that the obtained approximate solution of mass transfer equations is correct. They also show that the two-peak approximation facilitates finding k(+) and k(-) with a relative error of less than 10% if two peaks can be identified on a KCE electropherogram. Importantly, the condition of constant concentration of B is always satisfied in macroscopic approach to studying kinetics at equilibrium (MASKE) whether or not B is in excess to A* and C*, and, thus, the two-peak approximation is applicable to MASKE. It completes a toolset of fitting-free methods for processing MASKE data and makes MASKE a simple practical method for finding k(+) and k(-) of "fast", "slow", and "intermediate-rate" non-covalent interactions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Aciclovir and its Related Substance Guanine in Bulk Drug and Tablet Preparation by Capillary Electrophoresis

Two Capillary Zone electrophoresis (CZE) methods were developed in this study, one using an acidic buffer (sodium citrate pH = 2.5) and the other using a basic buffer (sodium tetraborate pH = 9.8). The two methods were compared on the basis of repeatability and reproducibility of results and the CZE method developed with the basic buffer was then selected for further studies. The method was ful...

متن کامل

Effect of Capillary Rinsing Protocol on the Reproducibility of Separation in Capillary Electrophoresis with Indirect UV Detection

Capillary electrophoresis (CE) with indirect UV detection is an interesting analytical method for the analysis of drugs and pharmaceuticals. Good and reproducible capillary quality is needed to develop robust methods and to facilitate method transfer in CE. It is widely accepted that preconditioning procedures are indispensable in capillary electrophoresis in order to achieve reproducibility of...

متن کامل

Effect of Capillary Rinsing Protocol on the Reproducibility of Separation in Capillary Electrophoresis with Indirect UV Detection

Capillary electrophoresis (CE) with indirect UV detection is an interesting analytical method for the analysis of drugs and pharmaceuticals. Good and reproducible capillary quality is needed to develop robust methods and to facilitate method transfer in CE. It is widely accepted that preconditioning procedures are indispensable in capillary electrophoresis in order to achieve reproducibility of...

متن کامل

Determination of Aciclovir and its Related Substance Guanine in Bulk Drug and Tablet Preparation by Capillary Electrophoresis

Two Capillary Zone electrophoresis (CZE) methods were developed in this study, one using an acidic buffer (sodium citrate pH = 2.5) and the other using a basic buffer (sodium tetraborate pH = 9.8). The two methods were compared on the basis of repeatability and reproducibility of results and the CZE method developed with the basic buffer was then selected for further studies. The method was ful...

متن کامل

Pressure-based approach for the analysis of protein adsorption in capillary electrophoresis.

Protein adsorption to inner capillary walls creates a major obstacle in all applications of capillary electrophoresis involving protein samples. The problem is especially severe in kinetic capillary electrophoresis (KCE) techniques, which are used to study protein-ligand interactions at physiological conditions and, thus, cannot utilize extreme pH. A variety of coatings exist to reduce protein ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Analyst

دوره 137 7  شماره 

صفحات  -

تاریخ انتشار 2012