Column-switching high-performance liquid chromatographic method for determination of a new antiviral agent, cyclaradine, in serum.

نویسندگان

  • J M Lim
  • C C Lin
چکیده

Cyclaradine is a novel carbocyclic nucleoside with good activity against the viruses of the herpes group. To facilitate pharmacokinetic studies on cyclaradine, an automated column-switching high-performance liquid chromatographic (HPLC) method was developed for the determination of cyclaradine in serum. Deproteinized serum containing cyclaradine was directed to an on-line extraction column which retained cyclaradine while many potentially interfering components were eluted to waste. Fourteen minutes later, the switching valve was automatically rotated, permitting an appropriate mobile phase to elute cyclaradine from the extraction column onto an analytical C18 column for further separation and UV detection. The method showed excellent linearity (r = 0.9995) for cyclaradine concentrations ranging from 0.05 to 5 micrograms/ml. It also provided good sensitivity (0.05 micrograms/ml). The assay was precise, with within-run and between-run coefficients of variation of less than 1.90%. The accuracy, expressed as differences between observed values and theoretical values, ranged from -4.12 to 4.80%. The assay involves a simple deproteinization of serum followed by a fully automated sample cleanup, eliminating long and tedious manual extraction prior to HPLC. The column-switching HPLC method has been successfully used for the determination of cyclaradine serum levels in squirrel monkeys following a single oral dose of 20 mg/kg.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High Performance Liquid Chromatographic Determination of Inactive Carboxylic Acid Metabolite of Clopidogrel in Human Serum: Application to a Bioequivalence Study

        A sensitive and rapid method is described for determination of clopidogrel carboxylic acid (CCA), the inactive metabolite of the antiplatelet agent clopidogrel in human serum. The analytical procedure involves liquid-liquid extraction of the analyte and an internal standard (phenytoin) with ethyl acetate. A mobile phase consisting of 0.05 M phosphate buffer containing triethylamine (0.5...

متن کامل

HIGH-PERFORMANCE LIQUID CHROMATOGRAPHIC DETERMINATION OF THEOPHYLLINE IN HUMAN SERUM

A simple, rapid and sensitive HPLC method for the determination of theophylline (T) in human serum has been developed. An isocratic system consisting of a /-l Bondapak C18 column, mobile phase of methanol, phosphate buffer (22:78, pH=4.5), and a flow rate of 1.4 mL/min was used. The eluent was detected by UV at 275 nm at room temperature. 8-Chlorotheophylline (8-CT) was used as an internal ...

متن کامل

Simple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma

A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...

متن کامل

Simple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma

A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...

متن کامل

A Reversed Phase High Performance Liquid Chromatographic Method for Determination of Rapamycin

Easily degradating and various isomeric forms of rapamycin (Sirolimus) face the determination of this compound to many challenges. In this study, we developed and validated the isocratic reversed phase high performance liquid chromatographic (RP-HPLC) method for rapamycin. Separation was performed on a C8 column (MZ, 15 × 4.6 mm, 5 µm particle size) using methanol:water (80:20 v/v) as the mobil...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Antimicrobial agents and chemotherapy

دوره 29 6  شماره 

صفحات  -

تاریخ انتشار 1986