The role of the cuff leak test in predicting the effects of corticosteroid treatment on postextubation stridor.

نویسندگان

  • Chih-Liang Wang
  • Ying-Huang Tsai
  • Chung-Chi Huang
  • Yau-Kwang Wu
  • Ming-Zhu Ye
  • Hsiu-Min Chou
  • Shih-Chun Shu
  • Meng-Chih Lin
چکیده

BACKGROUND There is not enough evidence to determine the most appropriate treatment of postextubation stridor. Although the cuff leak test is a simple method to predict postextubation stridor, little is known about its use in monitoring the effects of steroid treatment for this complication. The aim of this study was to evaluate the effect of steroids on postextubation stridor based on the clinical response and the cuff leak test. METHODS A cohort of 110 translaryngeal intubated patients in the medical intensive care unit (ICU) were enrolled. A cuff leak test was conducted before extubation. Patients developing postextubation stridor were intravenously given 5 mgs of dexamethasone every 8 hours for 3 days. The clinical response and cuff leak volume before and after steroid treatment were gathered for analysis. RESULTS The incidence of postextubation stridor was 18.2% (20/110). Fifty-five percent of patients (11/20) with stridor needed reintubation. Overall, 80% of patients (16/20) with postextubation stridor improved with steroid treatment. The leak volume significantly increased after treatment (152.4 +/- 109.6 ml vs. 29.9 +/- 35.7 ml, p = 0.012); stridor did not recur in 64% of reintubated patients (7/11). A threshold leak volume of less than 88 ml predicted the occurrence of stridor (positive predictive value, 54.5%; negative predictive value, 90.9%). Postextubation stridor was associated with the female gender and lower leak volumes (p = 0.007 and 0.003, respectively). CONCLUSION Corticosteroids improve postextubation stridor. The cuff leak test accurately predicts the absence of stridor and is a non-invasive method of monitoring for regression of laryngeal edema after steroid treatment. Steroid treatment should be considered for patients developing postextubation stridor.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Laryngeal Ultrasonography Versus Cuff Leak Test in Predicting Postextubation Stridor

INTRODUCTION Although cuff leak test has been proposed as a simple method of predicting the occurrence of postextubation stridor, cut-off point of cuff-leak volume substantially differs between previous studies. In addition, laryngeal ultrasonography including measurement of air column width could predict postextubation stridor. The aim of the present study was to evaluate the value of laryngea...

متن کامل

Intravenous injection of methylprednisolone reduces the incidence of postextubation stridor in intensive care unit patients.

OBJECTIVE To determine whether treatment with corticosteroids decreases the incidence of postextubation airway obstruction in an adult intensive care unit. DESIGN Clinical experiment. SETTING Adult medical and surgical intensive care unit of a teaching hospital. PATIENTS One hundred twenty-eight patients who were intubated for >24 hrs with a cuff leak volume <24% of tidal volume and met w...

متن کامل

Limited value of the cuff-leak test.

Stridor following tracheal extubation occurs in approximately 5% of all patients, and approximately 1% of all patients require reintubation for upper-airway obstruction.1 Patients at increased risk for stridor and upper-airway obstruction following extubation include female patients; children,2 particularly those with acute respiratory-tract infections (croup);3 patients who have incurred facia...

متن کامل

Postextubation laryngeal edema and stridor resulting in respiratory failure in critically ill adult patients: updated review

Endotracheal intubation is frequently complicated by laryngeal edema, which may present as postextubation stridor or respiratory difficulty or both. Ultimately, postextubation laryngeal edema may result in respiratory failure with subsequent reintubation. Risk factors for postextubation laryngeal edema include female gender, large tube size, and prolonged intubation. Although patients at low ri...

متن کامل

The endotracheal tube cuff-leak test as a predictor for postextubation stridor.

BACKGROUND The endotracheal tube (ETT) cuff-leak test (CLT) has been proposed as a relatively simple, noninvasive method for detecting the presence of laryngeal edema prior to tracheal extubation. OBJECTIVE To determine the value of the CLT for predicting postextubation stridor (PES) among medical and surgical patients, and to assess the impact of certain variables on the incidence of PES. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chang Gung medical journal

دوره 30 1  شماره 

صفحات  -

تاریخ انتشار 2007