Flow-through spectrophotometric sensor for the determination of aspartame in low-calorie and dietary products.

نویسندگان

  • L F Capitán-Vallvey
  • M C Valencia
  • E Arana Nicolás
چکیده

A very simple flow-through sensor is presented for the determination of the intense sweetener aspartame in low-calorie and dietary products. The sensor is implemented in a monochannel flow-injection system with UV spectrophotometric detection using a Sephadex CM-C25 cationic exchanger packed 20 mm high in a flow cell. This method is based on the transient retention of a cationic species of the sweetener on the solid phase when a pH 5.0 acetic acid sodium acetate buffer (0.01 M) is used as a carrier (2.6 mL(-1) min). The carrier itself elutes the analyte from the solid support, regenerating a sensing zone. Aspartame was determined by measuring its intrinsic absorbance at 219 nm at its residence time without any derivatization. Calibration graphs were linear over the range of 5.0 - 600.0 microg mL(-1) with an RSD of 0.55% (peak height). This sweetener was determined in several samples by measuring the height or peak area, obtaining recoveries ranging between 95 - 101% and 97.5 - 101%, respectively. The procedure was validated for its use in the determination of aspartame in low-calorie and dietary products, giving reproducible and accurate results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flow-through spectrophotometric sensor for the determination of saccharin in low-calorie products.

A simple, rapid and inexpensive monoparameter flow-through sensor has been developed for the determination of saccharin in low calorie and dietary products. The method is based on the transient adsorption of the sweetener on Sephadex G-25 solid phase packed to a height of 20 mm in the flow cell. The optimal transient retention of the synthetic sweetener, in terms of sensitivity and sampling fre...

متن کامل

Resolution of an intense sweetener mixture by use of a flow injection sensor with on-line solid-phase extraction. Application to saccharin and aspartame in sweets and drinks.

An integrated solid-phase spectrophotometry-FIA method is proposed for simultaneous determination of the mixture of saccharin (1,2-benzisothiazol-3(2H)-one-1,1-dioxide; E-954) (SA) and aspartame (N-L-alpha-aspartyl-L-phenylalanine-1-methyl ester; E-951) (AS). The procedure is based on on-line preconcentration of AS on a C18 silica gel minicolumn and separation from SA, followed by measurement, ...

متن کامل

Enzymatic spectrophotometric reaction rate determination of aspartame

Aspartame is an artificial sweetener of low caloric value (approximately 200 times sweeter than sucrose). Aspartame is currently permitted for use in food and beverage production in more than 90 countries. The application of aspartame in food products requires development of rapid, inexpensive and accurate method for its determination. The new assay for determination of aspartame was based on s...

متن کامل

Genotoxicity testing of low-calorie sweeteners: aspartame, acesulfame-K, and saccharin.

Low-calorie sweeteners are chemicals that offer the sweetness of sugar without the calories. Consumers are increasingly concerned about the quality and safety of many products present in the diet, in particular, the use of low-calorie sweeteners, flavorings, colorings, preservatives, and dietary supplements. In the present study, we evaluated the mutagenicity of the three low-calorie sweeteners...

متن کامل

Design and Evaluation and Synthesis a Starch-Capped Silver NanoParticles Sensor and Determination trace Sulfacetamide Drug in the Presence Sodium borohydride in Blood and Urine Samples with Kinetic Spectrophotometric Method

A new Kinetic Spectrophotometic method for the Determination of trace amount Sulfacetamide Drug into real samples has been described based with silver nanoparticles starch-capped sensor, by sodium borohydride. The reaction is followed spectrophotometrically by measuring the decrease in the absorbance at 347.5 nm. 1.0×10-2 molL-1 silver nanoparticles starch-capped sensor, 2.0×10-3 mol L-1 sodium...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 20 10  شماره 

صفحات  -

تاریخ انتشار 2004