Coronary flow velocity reserve after percutaneous interventions is predictive of periprocedural outcome.
نویسندگان
چکیده
BACKGROUND Because heterogeneous results have been reported, we assessed coronary flow velocity changes in individuals who underwent percutaneous transluminal coronary angioplasty (PTCA) and examined their impact on clinical outcome. METHODS AND RESULTS As part of the Doppler Endpoints Balloon Angioplasty Trial Europe (DEBATE) II study, 379 patients underwent Doppler flow-guided angioplasty. All patients were evaluated according to their coronary flow velocity reserve (CFVR) results (> or =2.5 or < 2.5) at the end of the procedure. A CFVR < 2.5 after angioplasty was associated with an elevated baseline blood flow velocity in both the target artery and reference artery. CFVR before PTCA and CFVR in the reference artery were independent predictors of an optimal CFVR after balloon angioplasty (CFVR before PTCA: odds ratio [OR], 2.26; 95% confidence interval [CI], 1.57 to 3.24; CFVR in reference artery: OR, 1.90; 95% CI, 1.21 to 2.98; both P<0.001) and stent implantation (before PTCA: OR, 2.54; 95% CI, 1.47 to 4.36; reference artery: OR, 1.97; 95% CI, 1.07 to 3.87; both P<0.05). A low CFVR at the end of the procedure was an independent predictor of major adverse cardiac events (MACE) at 30 days (OR, 4.71; 95% CI, 1.14 to 25.92; P=0.034) and at 1 year (OR, 2.06; 95% CI, 1.16 to 3.66; P=0.014). After excluding MACE at 30 days, no difference in MACE at 1 year was observed between the patients with and without a CFVR < 2.5 at the end of the procedure. CONCLUSIONS A low postprocedural CFVR was associated with a worse periprocedural outcome (which was related to microcirculatory disturbances), but there was no significant difference at late follow-up.
منابع مشابه
Change in coronary blood flow after percutaneous coronary intervention in relation to baseline lesion physiology: results of the JUSTIFY-PCI study.
BACKGROUND Percutaneous coronary intervention (PCI) aims to increase coronary blood flow by relieving epicardial obstruction. However, no study has objectively confirmed this and assessed changes in flow over different phases of the cardiac cycle. We quantified the change in resting and hyperemic flow velocity after PCI in stenoses defined physiologically by fractional flow reserve and other pa...
متن کاملDetection of coronary microembolization by Doppler ultrasound in patients with stable angina pectoris undergoing elective percutaneous coronary interventions.
BACKGROUND Intracoronary Doppler guidewires can be used for real-time detection and quantification of microembolism during percutaneous coronary interventions (PCIs). We investigated whether the frequency of Doppler-detected microembolism is related to the incidence of myonecrosis during elective PCI. METHODS AND RESULTS The study population included 52 consecutive patients (aged 64+/-10 year...
متن کاملLetter by Layland et al regarding article, "Validation of intravascular ultrasound-derived parameters with fractional flow reserve for assessment of coronary stenosis severity".
To the Editor: We read with great interest the study by Kang et al 1 that explored the relationship between intravascular ultrasound parameters and fractional flow reserve (FFR) in the assessment of intermediate coronary stenoses. 1 We congratulate the authors, who concluded that lesions with a mean luminal area of Ͻ2.4 mm 2 had a high sensitivity and negative predictive value to predict FFR Ͻ0...
متن کاملSingle-wire pressure and flow velocity measurement to quantify coronary stenosis hemodynamics and effects of percutaneous interventions.
BACKGROUND Lack of high-fidelity simultaneous measurements of pressure and flow velocity distal to a coronary artery stenosis has hampered the study of stenosis pressure drop-velocity (DeltaP-v) relationships in patients. METHODS AND RESULTS A novel 0.014-inch dual-sensor (pressure and Doppler velocity) guidewire was used in 15 coronary lesions to obtain per-beat averages of pressure drop and...
متن کاملRepair of all the components of the syndrome of aortic regurgitation and VSD.
Heyndrickx GR. Intracoronary and intravenous adenosine 50-triphosphate, adenosine, papaverine, and contrast medium to assess fractional flow reserve in humans. Circulation 2003;107:1877–1883. 21. Pijls N, van Son J, Kirkeeide R, De Bruyne B, Gould K. Experimental basis of determining maximum coronary, myocardial, and collateral blood flow by pressure measurements for assessing functional stenos...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 105 13 شماره
صفحات -
تاریخ انتشار 2002