Between-method correlation in quantifying internal carotid stenosis.
نویسندگان
چکیده
BACKGROUND AND PURPOSE The degree of internal carotid stenosis has emerged as the most important predictor of ischemic stroke in extracranial carotid artery disease. The purpose of this study was to assess the validity of the noninvasive techniques for quantifying internal carotid stenosis with respect to the accepted standard of intra-arterial angiography. METHODS We measured the maximum percentage reduction in luminal diameter on the intra-arterial digital subtraction angiograms of 56 symptomatic patients with extracranial internal carotid stenosis (n = 77) or occlusion (n = 20). These data were compared with independent measurements based on continuous-wave Doppler ultrasonography, pulsed-wave Doppler spectrum analysis, color Doppler-assisted duplex imaging, and magnetic resonance angiography. RESULTS Correlations with intra-arterial angiography were equally strong (r > .90) for magnetic resonance angiography, continuous-wave Doppler, and color duplex analysis. Positive and negative predictive values for (therapeutically relevant) 70% to 99% stenosis were higher for continuous-wave Doppler (.82, .97) and color duplex (.84, .98) than for magnetic resonance angiography (.79, .81). Also, accuracy in quantifying high-grade stenosis was better for both of these ultrasonographic techniques, mainly due to the frequent occurrence of a "flow gap" on the magnetic resonance angiograms. Continuous-wave Doppler and magnetic resonance angiography, but not color duplex, failed to detect slow residual arterial flow in one and two cases of symptomatic "pseudo-occlusion" of the internal carotid, respectively. CONCLUSIONS (1) Several noninvasive methods compare well with intra-arterial angiography in identifying and quantifying high-grade internal carotid stenosis; (2) the use of these noninvasive methods may suffice for treatment decisions; and (3) because residual between-method disagreement is partly explained by principles of physics, the validity of continuous-wave Doppler and color duplex in quantifying 60% to 99% stenosis is likely to be underestimated by correlation with intra-arterial angiography.
منابع مشابه
بررسی تنگی عروق کاروتید داخلی در مبتلایان به حملات ایسکمی گذرا در بیمارستان امام خمینی در سال های 1375 تا 1377
This is a prospective descriptive research which was carried out in Imam Khomeini Hospital related to Tehran University during two years (1375-1377) in order to study the incidence of internal carotid stenosis in patients who suffered from TIA ot minor stroke. It was evaluated by duplex sonography. Risk factors of carotid stenosis were studied. 1052 patients who had cerebrovascular accident adm...
متن کاملA Lumped Parameter Method to Calculate the Effect of Internal Carotid Artery Occlusion on Anterior Cerebral Artery Pressure Waveform
Background and Objective: Numerical modeling of biological structures would be very helpful tool to analyze hundreds of human body phenomena and also diseases diagnosis. One physiologic phenomenon is blood circulatory system and heart hemodynamic performance that can be simulated by utilizing lumped method. In this study, we can predict hemodynamic behavior of one artery of circulatory system (...
متن کاملCarotid angioplasty and stenting in a patient with high grade stenosis of Internal Carotid Artery associated with both vertebral arteries and contralateral carotid occlusion
Severe internal carotid artery (ICA) stenosis is a common cause of cerebrovascular accident (CVA) in middle-aged patients. Contralateral carotid occlusion (CCO) in patients with severe ICA stenosis is associated with high risk of CVA. Carotid endarterectomy (CEA) is associated with more complications in patients with CCO than those without CCO. In this study, we present the case of a 61-year-ol...
متن کاملReproducibility of semi-automated measurement of carotid stenosis on CTA.
PURPOSE To compare the reproducibility of semi-automated vessel analysis software to manual measurement of carotid artery stenosis on computed tomography angiography (CTA). METHODS Two observers separately analyzed 81 carotid artery CTAs using semi-automated vessel analysis software according to a blinded protocol. The software measured the narrowest stenosis in millimeters (mm), distal inter...
متن کاملThe value of regional cerebral blood flow measurements compared to angiography in the assessment of obstructive neck vessel disease.
AND L. EHRMANN, M.D.* Abstract: The Value of Regional Cerebral Blood Flow Measurements Compared to A ngiography in the Assessment of Obstructive Neck Vessel Disease • In 50 patients with internal carotid artery occlusion and 40 patients with internal carotid artery stenosis hemispheric and regional cerebral blood flow (rCBF) was measured by the Xenon clearance method. rCBF was evaluated accordi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Stroke
دوره 24 10 شماره
صفحات -
تاریخ انتشار 1993