Inspection of lead aprons: criteria for rejection.
نویسندگان
چکیده
Lead aprons utilized by personnel performing fluoroscopy are routinely inspected for damage to comply with the requirements of hospital accrediting organizations. Fluoroscopic or radiographic examination of lead aprons may reveal imperfections ranging from small pinholes to large tears. Currently, there are no standards establishing a criteria for acceptance or rejection of lead aprons. As a consequence, many facilities have established arbitrary rejection criteria. Often lead aprons are discarded due to small imperfections, a practice that can become costly to these institutions. We have calculated increases in doses to the whole body for varying sizes of holes, including special consideration of the effects on effective dose equivalent when the hole is over the testes and thyroid. ALARA standards for cost per personsievert averted are used to establish a rational basis for criteria of acceptance or rejection of lead aprons.
منابع مشابه
Inspection of lead aprons: a practical rejection model.
As a sequel to the article by Ken Lambert and Tara McKeon, we propose a model by which defects in lead aprons may easily be evaluated on a routine basis. The model is applicable to lead aprons of various lead equivalent thicknesses. As recommended rejection criteria, we have used the concept of additional dose that an individual might receive due to defects in the lead (Pb) apron. The model has...
متن کاملEvaluation of X-ray protective shielding used in dental offices in Kerman, Iran, in 2014
BACKGROUND AND AIM: Protective equipment, such as lead aprons and thyroid shields, is effective in reducing patient radiation. This study was conducted for evaluation the use of thyroid shields and lead aprons in dental offices, in Kerman, Iran, in June 2014.METHODS: In this descriptive-analytical study, 106 dental offices with active X-ray machines were evaluated in Kerman. The information was...
متن کاملUsefulness of non-lead aprons in radiation protection for physicians performing interventional procedures.
At present, interventional radiology (IVR) tends to involve long procedures (long radiation duration), and physicians are near to the source of scattered radiation. Hence, shielding is critical in protecting physicians from radiation. Protective aprons and additional lead-shielding devices, such as tableside lead drapes, are important means of protecting the physician from scattered radiation. ...
متن کاملImplementation of an X-ray radiation protective equipment inspection program.
In order to comply with the requirements established by healthcare organization accrediting agencies, radiation protective equipment (e.g., lead aprons, gloves, and collars) utilized by x-ray workers must be periodically evaluated for damage. The objective of such evaluations is to identify and remove from service equipment bearing large holes, tears, etc., that could compromise the safety of i...
متن کاملEvaluation of the transmitted exposure through lead equivalent aprons used in a radiology department, including the contribution from backscatter.
A study was conducted to evaluate the radiation transmission through lead equivalent aprons that are used in a radiology department. A large area beam (poor geometry) was employed for the transmission measurements, and backscatter was simulated by placing 7" of Lucite behind each apron. Separate ionization chambers were used to measure the incident and transmitted x-ray beams. Transmission meas...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Health physics
دوره 80 5 Suppl شماره
صفحات -
تاریخ انتشار 2001