Ion-trap detection of volatile organic compounds in alveolar breath.

نویسندگان

  • M Phillips
  • J Greenberg
چکیده

We describe a method for the collection and microanalysis of the volatile organic compounds in human breath. A transportable apparatus supplies subjects with purified air and samples their alveolar breath; the volatile organic compounds are captured in an adsorptive trap containing activated carbon and molecular sieve. The sample is thermally desorbed from the trap in an automated microprocessor-controlled device, concentrated by two-stage cryofocusing, and assayed by gas chromatography with ion-trap detection. Compounds are identified by reference to a computer-based library of mass spectra with subtraction of the background components present in the inspired air. We used this device to study 10 normal subjects and determined the relative abundance of the volatile organic compounds in their alveolar breath. The breath-collecting apparatus was convenient to operate and was well tolerated by human volunteers.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

O-Toluidine in Breath-Non-Invasive Prilocaine Monitoring

The generation of methaemoglobin is a rare but potential life-threatening side effect in the use of the local anaesthetic prilocaine. It is currently only possible to ensure the diagnosis by means of blood tests. Rapid noninvasive diagnosis is desirable, especially for risk patients. Using a pig model, we induced methaemoglobinemia via application of dimethyl aminophenol and prilocaine (setup I...

متن کامل

Recent Advances in Microextraction Methods for Sampling and Analysis of Volatile Organic Compounds in Air: A Review

Human exposures to volatile organic compounds (VOCs) are associated with a wide range of health problems. Due to these adverse effects of VOCs on the human health, determination of trace levels of VOCs is very important for accurate assessment of indoor and outdoor exposure. Solid phase microextraction (SPME), needle trap device (NTD) and hollow fiber- liquid phase microextraction (HF-LPME) are...

متن کامل

Multibed needle trap devices for on site sampling and preconcentration of volatile breath biomarkers.

To facilitate their use in trace gas analysis, the adsorption capacity of needle trap devices (NTDs) was increased by combining three adsorbent materials and increasing total adsorbent amount. The use of 22 gauge needles, application of internally expanding desorptive flow technique without cryofocusation and a new on site alveolar sampling method for NTDs provided sensitivity in the parts per ...

متن کامل

Detection of volatile organic compounds in breath using thermal desorption electrospray ionization-ion mobility-mass spectrometry.

A thermal desorption unit has been interfaced to an electrospray ionization-ion mobility-time-of-flight mass spectrometer. The interface was evaluated using a mixture of six model volatile organic compounds which showed detection limits of <1 ng sample loaded onto a thermal desorption tube packed with Tenax, equivalent to sampled concentrations of 4 microg L(-1). Thermal desorption profiles wer...

متن کامل

Breath analysis as a technique in clinical chemistry.

Breath possesses unique advantages as a specimen for clinical chemical analyses, including the continuous equilibrium of gases and volatile substances between expired alveolar air and the pulmonary blood circulation. Substances amenable to analysis in breath include 02, C02, CO,and other gases, volatile organic compounds, and many drugs with sufficiently high vapor pressures at physiological te...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 38 1  شماره 

صفحات  -

تاریخ انتشار 1992