Depth-dose distribution of proton beams using inelastic-collision cross sections of liquid water
نویسندگان
چکیده
0168-583X/$ see front matter 2010 Elsevier B.V. doi:10.1016/j.nimb.2010.10.013 ⇑ Corresponding author. E-mail addresses: [email protected], mortez [email protected] (M. Aslaninejad). Complete physical processes contributing to the shape of the depth-dose distribution and the so-called Bragg peak of proton beams passing through liquid water are given. Height, width and depth of the Bragg peak through investigation of collisions of the projectile, nuclear processes and stochastic phenomena are discussed. Different analytical models for stopping cross sections which lead to Bragg peak are contrasted. Results are also compared with GEANT4 package simulation. 2010 Elsevier B.V. All rights reserved.
منابع مشابه
A method for range calculation of proton in liquid water: Validation study using Monte Carlo method and NIST data
Introduction: The main advantage of using ion beams over photons in radiotherapy is due to their inverse depth-dose profiles, allowing higher doses to tumors, while better sparing normal tissues. When calculating dose distributions with ion beams, one crucial point is the uncertainty of the Bragg-peak range. Recently great effort is devoted to enhance the accuracy of the comput...
متن کاملAssessment of secondary particles in breast proton therapy by Monte Carlo simulation code using MCNPX
Background: The present study aimed to investigate the equivalent dose in vital organs, including heart and lung, due to secondary particles produced during breast proton therapy. Materials and Methods: The numerical ORNL female-phantom was improved and simulated using the Monte Carlo MCNPX code. The depth-dose profile of proton beams with different energies was simulated. The proper energy ran...
متن کاملInclusive high Q cross sections and QCD and EW fits at HERA
The latest measurements of the cross sections for neutral and charged current deep inelastic scattering in ep collisions at HERA with longitudinally polarised lepton beams are presented. The measured cross sections are compared with the predictions of the Standard Model. Next-to-leading-order QCD analyses of HERA data are also presented. The analyses yield the parton distribution functions of t...
متن کاملAssessment of The Relation Between Energy Of Primary Protons And Undesired Neutron Dose During Proton Therapy By Monte Carlo Method
Introduction: High-energy beams of protons offer significant advantages for the treatment of deepseated local tumors. Their physical depth-dose distribution in tissue is characterized by a small entrance dose and a distinct maximum -Bragg peak- near the end of range with a sharp fall-off at the distal edge. Alongside its advantages there are some point that they need to meticul...
متن کاملStatistical uncertainty estimation in the calculation of the proton range in water phantom.
Introduction: GATE (Geant4 Application for Tomographic Emission) is a Monte Carlo simulation platform developed by the OpenGATE collaboration since 2001 and first publicly released in 2004. In Geant4, each physics process is described by a model (several models are sometimes available for a given physics process) and a corresponding cross-section table. All Geant4 physics model...
متن کامل