Innovative Methodology Mapping and quantifying hyperpolarized He magnetic resonance imaging apparent diffusion coefficient gradients
نویسندگان
چکیده
Evans A, McCormack DG, Santyr G, Parraga G. Mapping and quantifying hyperpolarized He magnetic resonance imaging apparent diffusion coefficient gradients. J Appl Physiol 105: 693–699, 2008. First published June 5, 2008; doi:10.1152/japplphysiol.00178.2008.—We measured hyperpolarized He magnetic resonance imaging (MRI) apparent diffusion coefficients (ADC) and quantified ADC gradients in each threeby-three voxel region of interest (ROI). Such local ADC gradients can be represented in vector maps showing the magnitude ( G3 3 ) and direction of ADC gradients, providing a qualitative visualization tool and quantitative measurement of airway and air space heterogeneity. Twenty-four subjects (15 male, mean age 67 7 yr) with global initiative for chronic obstructive lung disease (GOLD) stage II (n 9, mean age 68 6 yr), GOLD stage III chronic obstructive pulmonary disease (COPD; n 7, mean age 67 8 yr), and age-matched healthy volunteers (n 8, mean age 67 6 yr) were enrolled based on their age and spirometry results. Hyperpolarized He MRI was performed on a whole body 3.0 Tesla system. Mean He ADC and ADC standard deviation were calculated for the center coronal slice, and the mean magnitude and direction of the ADC gradient vectors were calculated for each three-by-three voxel matrix ( G3 3 ). While the He ADC standard deviation was not significantly different, mean G3 3 was significantly different between subjects with stage II (0.14 0.03 cm/s) and stage III COPD (0.19 0.03 cm/s; P 0.005) and between healthy subjects (0.12 0.03 cm/s) and those with stage II COPD (P 0.02). The second order statistic G3 3 may provide a sensitive measure of ADC heterogeneity for ROI representing 9.4 9.4 30 mm or 2.6 cm of lung tissue.
منابع مشابه
Iology Contribution Proton and Hyperpolarized Helium Magnetic Resonance Imaging of Radiation-induced Lung Injury in Rats
Purpose: To assess the usefulness of hyperpolarized helium (He) MRI, including apparent diffusion coefficient measurements, in the detection and evaluation of radiation-induced lung injury in rats. Methods and Materials: Female Fischer-344 rats were treated to the right lung with fractionated dose of 40 Gy (5 8 Gy) using 4-MV photons. Conventional proton (H) and hyperpolarized (He) MRI were use...
متن کاملMeasurement of Apparent Long-Range Diffusion of He using Pulsed Gradient Spin Echo T2 in the Rat Lung at Low Magnetic Field Strength
Introduction: Measurement of Apparent Diffusion Coefficients (ADC) of hyperpolarized He gas in the lungs, can provide information on the micro-anatomical changes associated with disease over length scales permitted by the diffusion time. Improved sensitivity of ADC to chronic obstructive pulmonary disease (COPD) has recently been demonstrated using diffusion times on the order of seconds. These...
متن کاملHyperpolarized He magnetic resonance imaging-derived pulmonary pressure-volume curves
Choy S, Wheatley A, McCormack DG, Parraga G. Hyperpolarized He magnetic resonance imaging-derived pulmonary pressurevolume curves. J Appl Physiol 109: 574–585, 2010. First published June 10, 2010; doi:10.1152/japplphysiol.01085.2009.—We aimed to evaluate the potential for the use of hyperpolarized helium-3 magnetic resonance imaging (MRI) apparent diffusion coefficient (ADC) surrogates of alveo...
متن کاملGas diffusion in a pulmonary acinus model: experiments with hyperpolarized helium-3.
Diffusion of hyperpolarized helium-3 in epoxy phantoms was experimentally studied by pulsed-gradient nuclear magnetic resonance (NMR). One phantom with a dichotomic branching structure densely filling a cubic volume was built using the Kitaoka algorithm to model a healthy human acinus. Two other phantoms, one with a different size and the other one with a partial destruction of the branched str...
متن کاملIn vivo NMR of hyperpolarized 3He in the human lung at very low magnetic fields.
We present NMR measurements of the diffusion of hyperpolarized 3He in the human lung performed at fields much lower than those of conventional MRI scanners. The measurements were made on standing subjects using homebuilt apparatus operating at 3mT. O(2)-limited transverse relaxation (T(2) up to 15-35s) could be measured in vivo. Accurate global diffusion measurements have been performed in vivo...
متن کامل