Optimum electrode configuration for detection of leg movement using bio-impedance.

نویسندگان

  • Chul Gyu Song
  • Soo Chan Kim
  • Ki Chang Nam
  • Deok Won Kim
چکیده

Impedances and joint angles were simultaneously measured during ankle and knee movements. The correlation coefficients of the joint angle and the impedance change from human leg movement were obtained using an electro-goniometer and a four-channel impedance measurement system. Because the impedance changes resulting from ankle and knee movements depended heavily on the electrode placement, we determined the optimum electrode configurations for those movements by searching for high correlation coefficients, large impedance changes and minimum interferences in ten subjects (age: 20+/-4). Our optimum electrode configurations showed strong relationships between the ankle joint angle and lower leg impedance (correlation coefficient=-0.91+/-0.06) and between the knee joint angle and knee impedance (correlation coefficient=0.94+/-0.04). The reproducibilities of the impedance changes of five subjects due to the ankle and knee were 6.3+/-1.9% and 5.1+/-1.7% for the optimum electrode pairs, respectively. We propose that this optimum electrode configuration would be useful for future studies involving the convenient measurement of leg movements by the impedance method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A new approach for detection of leg movement using segmental electrical impedance changes.

The purpose of this paper is to provide a new approach for detection using bio-impedance. This impedance is measured by the four-electrode method. As the impedance changes resulting from ankle, knee, and hip movements depend on electrode placement, we determined the optimal electrode configurations for these movements by searching for high correlation coefficients, large impedance changes, and ...

متن کامل

The Application of Bioelectrical Impedance to Monitor Leg Movement

The purpose of this study is to provide a new approach for detection using bio-impedance. This impedance is measured by the four-electrode method. As the impedance changes resulting from ankle, knee, and hip movements depended heavily on electrode placement, we determined the optimal electrode configurations for those movements by searching for high correlation coefficients, large impedance cha...

متن کامل

Flexible Electrode Array for Retinal Stimulation

In this Work, ITO/PET (Indium Tin Oxide / Polyethylene Terephthalate) electrode structure which provides biocompatibility, mechanical stability and flexibility is fabricated. Flexible ITO/PET implantable electrode array for a retina has been developed. The electrode array is fabricated on a thin PET/ITO substrate and is encapsulated using, SU-8, an insulating material. PET substrate and SU-8 po...

متن کامل

Optimum conductive fabric sensor sites for evaluating the status of knee joint movements using bio-impedance

BACKGROUND There have been many studies that utilize the bio-impedance measurement method to analyze the movements of the upper and lower limbs. A fixed electrical current flows into the limbs through four standard disposable electrodes in this method. The current flows in the muscles and blood vessels, which have relatively low resistivity levels in the human body. This method is used to measu...

متن کامل

Quantative Evaluation of the Efficiency of Facial Bio-potential Signals Based on Forehead Three-Channel Electrode Placement For Facial Gesture Recognition Applicable in a Human-Machine Interface

Introduction: Today, facial bio-potential signals are employed in many human-machine interface applications for enhancing and empowering the rehabilitation process. The main point to achieve that goal is to record appropriate bioelectric signals from the human face by placing and configuring electrodes over it in the right way. In this paper, heuristic geometrical position and configuration of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physiological measurement

دوره 26 2  شماره 

صفحات  -

تاریخ انتشار 2005