Electrical conductivity measurement of excised human metastatic liver tumours before and after thermal ablation.

نویسندگان

  • Dieter Haemmerich
  • David J Schutt
  • Andrew W Wright
  • John G Webster
  • David M Mahvi
چکیده

We measured the ex vivo electrical conductivity of eight human metastatic liver tumours and six normal liver tissue samples from six patients using the four electrode method over the frequency range 10 Hz to 1 MHz. In addition, in a single patient we measured the electrical conductivity before and after the thermal ablation of normal and tumour tissue. The average conductivity of tumour tissue was significantly higher than normal tissue over the entire frequency range (from 4.11 versus 0.75 mS cm(-1) at 10 Hz, to 5.33 versus 2.88 mS cm(-1) at 1 MHz). We found no significant correlation between tumour size and measured electrical conductivity. While before ablation tumour tissue had considerably higher conductivity than normal tissue, the two had similar conductivity throughout the frequency range after ablation. Tumour tissue conductivity changed by +25% and -7% at 10 Hz and 1 MHz after ablation (0.23-0.29 at 10 Hz, and 0.43-0.40 at 1 MHz), while normal tissue conductivity increased by +270% and +10% at 10 Hz and 1 MHz (0.09-0.32 at 10 Hz and 0.37-0.41 at 1 MHz). These data can potentially be used to differentiate tumour from normal tissue diagnostically.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ex vivo electrical impedance measurements on excised hepatic tissue from human patients with metastatic colorectal cancer.

Point-wise ex vivo electrical impedance spectroscopy measurements were conducted on excised hepatic tissue from human patients with metastatic colorectal cancer using a linear four-electrode impedance probe. This study of 132 measurements from 10 colorectal cancer patients, the largest to date, reports that the equivalent electrical conductivity for tumor tissue is significantly higher than nor...

متن کامل

Correction to: Efficacy of Radiofrequency Ablation in Patients with Metastatic Liver Tumors from Breast Carcinoma

In the article published in Volume 27, issue 158, 2017, the Results section in English Abstract have been published incorrectly. The correct Results is given below:   Results: The most frequent sizes of mass were 2-4 cm (n=33, 54%) and 4-5 cm (n=23, 38%). Among the patients, 35 (67.3%) had one tumor before, in 11.5% renew tumor happened, and 65.4% had one tumor after treatment. Liver tum...

متن کامل

Influence of electrical and thermal properties on RF ablation of breast cancer: is the tumour preferentially heated?

BACKGROUND Techniques based on radio frequency (RF) energy have many applications in medicine, in particular tumour ablation. Today, mammography screening detects many breast cancers at an early stage, facilitating treatment by minimally invasive techniques such as radio frequency ablation (RFA). The breast cancer is mostly surrounded by fat, which during RFA-treatment could result in preferent...

متن کامل

Microwave Tumor Ablation of Vertebral Bone Metastasis: A Case Report

Introduction: Thermal ablation by microwave (MWA) has proven efficacy in treatment of primary and metastatic cancers. Soft tissue tumors could be ablated completely using MWA. However, bony tissue metastasis particularly spinal vertebral metastasis ablation has not reported yet. Case presentation: A 50 year old male patient with primary diagnosed colon cancer undergone surgical resection of ...

متن کامل

Image-guided radiofrequency ablation of liver malignancies: experience at Singapore General Hospital.

UNLABELLED The aim of this paper was to study the efficacy, side effects and complications of radiofrequency (RF) ablation of primary and metastatic liver malignancies. MATERIALS AND METHODS We retrospectively reviewed 57 patients (39 men, 18 women; mean age, 63 years; age range, 44 to 83 years) who underwent RF ablation for liver malignancies from January 2002 to December 2004. A total of 87...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physiological measurement

دوره 30 5  شماره 

صفحات  -

تاریخ انتشار 2009