Radiometric calibration of infrared imagers using an internal shutter as an equivalent external blackbody
نویسندگان
چکیده
Advances in microbolometer long-wave infrared (LWIR) detectors have led to the common use of infrared cameras that operate without active temperature stabilization, but the response of these cameras varies with their own temperature. Therefore, obtaining quantitative data requires a calibration that compensates for these errors. This paper describes a method for stabilizing the camera’s response through software processing of consecutive images of the scene and images of the camera’s internal shutter. An image of the shutter is processed so that it appears as if it were viewed through the lens. The differences between the scene and the image of the shutter treated as an external blackbody are then related to the radiance or temperature of the objects in the scene. This method has been applied to two commercial LWIR cameras over a focal plane array temperature range of 7.2°C, changing at a rate of up to 0.5°C∕min. During these tests, the rms variability of the camera output was reduced from 4.0°C to 0.26°C. © The Authors. Published by SPIE under a Creative Commons Attribution 3.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI. [DOI: 10.1117/1.OE.53.12.123106]
منابع مشابه
Imager-to-radiometer in-flight cross calibration: RSP radiometric comparison with airborne and satellite sensors
This work develops a method to compare the radiometric calibration between a radiometer and imagers hosted on aircraft and satellites. The radiometer is the airborne Research Scanning Polarimeter (RSP), which takes multi-angle, photo-polarimetric measurements in several spectral channels. The RSP measurements used in this work were coincident with measurements made by the Airborne Visible/Infra...
متن کاملCalibration of uncooled thermal infrared cameras
The calibration of uncooled thermal infrared (IR) cameras to absolute temperature measurement is a time-consuming, complicated process that significantly influences the cost of an IR camera. Temperaturemeasuring IR cameras display a temperature value for each pixel in the thermal image. Calibration is used to calculate a temperature-proportional output signal (IR or thermal image) from the meas...
متن کاملQuantitative Measurement of Illumination Invariance for Face Recognition Using Thermal Infrared Imagery∗
A key issue for face recognition has been accurate identification under variable illumination conditions. Conventional video cameras sense reflected light so that image gray values are a product of both intrinsic skin reflectivity and external incident illumination, obfuscating intrinsic reflectivity of skin. It has been qualitatively observed that thermal imagery of human faces is invariant to...
متن کاملIntercomparison of laboratory radiance calibration standards
Several standards for radiometric calibration were measured repeatedly with a spectroradiometer in order to understand how they compared in accuracy and stability. The tested radiance standards included a NIST 1000 W bulb and Spectralon panel, two calibrated and stabilized integrating spheres, and a cavity blackbody. Results indicate good agreement between the blackbody and 1000 W bulb/Spectral...
متن کاملHj-1a/b Multispectral Imagers Radiometric Stability in the First Year
On September 6th, 2008, HJ-1A/B, which is a Micro-satellite Constellation for Environment and Disaster Monitoring, was successfully launched in China. HJ-1A/B is composed by two small satellites named as Satellite-A (HJ-1A) and Satellite-B (HJ-1B). The payloads of HJ-1A include a multispectral imager and an interferometric imaging spectrometer; the payloads of HJ-1B include an infrared scanner ...
متن کامل