AB214. Application of ultrasonic measurement of epididymal width in differential diagnosis of azoospermia
نویسنده
چکیده
Objective: To investigate the of epididymal width in identifying non obstructive azoospermia (NOA) and obstructive azoospermia (OA). Methods: Using scrotal ultrasound to compare difference of epididymal width between OA (n=18) and NOA (n=10) patients. Results: In the patients with OA average bilateral epididymal width is 0.7+0.1 cm, which is higher than the NOA patients (P<0.05) by ultrasonic measurement. The average width of bilateral epididymis increased with the increase of Johnsen score (P<0.05). In ROC analysis, when 0.78, 0.33, 0.53 cm are used as the cut point for bilateral caput epididymis, corpus epididymis, cauda epididymis, respectively, the sensitivity for differential diagnosis is higher. Conclusions: There is obvious difference in epididymal width under ultrasound between NOA and OA, which is helpful for differential diagnosis of azoospermia.
منابع مشابه
AB215. Penis transplant: a long way to success
Objective: To investigate the of epididymal width in identifying non obstructive azoospermia (NOA) and obstructive azoospermia (OA). Methods: Using scrotal ultrasound to compare difference of epididymal width between OA (n=18) and NOA (n=10) patients. Results: In the patients with OA average bilateral epididymal width is 0.7+0.1 cm, which is higher than the NOA patients (P<0.05) by ultrasonic m...
متن کاملApplication of percutaneous epididymal sperm aspiration in azoospermia.
OBJECTIVE The present study introduces the application of percutaneous epididymal sperm aspiration (PESA) for diagnosis of obstructive azoospermia and non-obstructive azoospermia. PATIENTS AND METHODS 96 cases diagnosed with azoospermia were selected, standard methods were used to measure testicular volume, chemiluminescence was used to test serum sexual hormone levels, and No. 7 butterfly ne...
متن کاملApplication of Model-Based Estimation to Time-Delay Estimation of Ultrasonic Testing Signals
Time-Delay-Estimation (TDE) has been a topic of interest in many applications in the past few decades. The emphasis of this work is on the application of model-based estimation (MBE) for TDE of ultrasonic signals used in ultrasonic thickness gaging. Ultrasonic thickness gaging is based on precise measurement of the time difference between successive echoes which reflect back from the back wall ...
متن کاملRelationship between semen quality and the seminal plasma components carnitine, alpha-glucosidase, fructose, citrate and granulocyte elastase in infertile men compared with a normal population.
The seminal plasma components neutral alpha-glucosidase, carnitine, fructose, citrate, and polymorphonuclear granulocyte (PMN) elastase in 253 men were determined. The seminal plasma of 221 infertile men, a control group with proved fertility and 13 patients after vasectomy were investigated. The concentrations of free carnitine (212 versus 521 micromol/l, n = 219, P < 0.001), total carnitine (...
متن کاملStudy of the effect of energy window width and peak shift on SPECT images to evaluate false diagnosis
Introduction: The different factors that affect the camera uniformity of Single Photon Emission Computed Tomography (SPECT) technique have been analyzed including peak shift (%) and window width of energy. The effect of peak shift and window width on SPECT image uniformity has been investigated using a point source to perform intrinsic flood images. Methods:</stro...
متن کامل