Analysis of Transient Phenomena Due to a Direct Lightning Strike on a Wind Energy System
نویسندگان
چکیده
This paper is concerned with the protection of wind energy systems against the direct effects of lightning. As wind power generation undergoes rapid growth, lightning damages involving wind turbines have come to be regarded as a serious problem. Nevertheless, very few studies exist yet in Portugal regarding lightning protection of wind energy systems using numerical codes. A new case study is presented in this paper, based on a wind turbine with an interconnecting transformer, for the analysis of transient phenomena due to a direct lightning strike to the blade. Comprehensive simulation results are provided by using models of the Restructured Version of the Electro-Magnetic Transients Program (EMTP), and conclusions are duly drawn.
منابع مشابه
بررسی جامع اضافهولتاژهای صاعقه در مزارع بادی با پیکربندیهای متفاوت به همراه تاثیر سیستم زمین
This paper is treated with major risks applied by lightning strikes to wind farms. The risks illustrated in this research include overvoltage caused by direct and indirect effects of lightning strikes on any components of wind farm. As demands for electrical energy throughout our world is increased more and more nowadays, wind power plants are extended in every possible locations correspondingl...
متن کاملOne case of a lightning strike leads to death: case report
Background: Lightning is one of the most mysterious phenomena of nature that also, it has caused many financial and human losses. In tropical and sub-tropical countries, death due to thunderbolt is not unusual, and even tragic events may occur at high altitudes. Lightning physics is complex and not completely clear. Usually, the clouds are heavily pregnant and high voltages and amperages, they ...
متن کاملApplication of Intelligent Water Drops in Transient Analysis of Single Conductor Overhead Lines Terminated to Grid-Grounded Arrester under Direct Lightning Strikes
In this paper, Intelligent water drop algorithm (IWD) is used to analyze single overhead line connected to grid-grounded arrester. In this approach, at first Norton’s equivalent circuit of the overhead line over lossy soil is computed by method of moments (MoM) and then for the problem under consideration, a nonlinear equivalent circuit in the frequency domain is proposed. Finally applying inte...
متن کاملTransient Analysis of the Single-Conductor Overhead Lines Connected to Grid-Grounded Arrester under Direct Lightning by Means of GA
In this paper, genetic algorithm-based approach for transient analysis of single transmission line connected to arrester is proposed. In this approach, the lightning channel striking the overhead line is first represented by a current source and this source is truncated by a finite set of frequency harmonies in time domain. Norton equivalent circuit viewed across arrester is then computed by me...
متن کاملارائۀ یک روش نوین بهمنظور مدلسازی جامع سیستم زمین دکلهای فشار قوی و برج توربینهای بادی با استفاده از روش برازش برداری
In the past, grounding systems usually were modeled by an individual Resistor. This estimation is useful only at low frequencies, while in high frequencies, the inductance of the grounding system plays the main role to identify the phase and amplitude of that. In recent years, as wind farms grow rapidly throughout the world, the grounding system and ground impedance of wind turbine towers under...
متن کامل