Reduced amount of gaseous microemboli in the arterial line of minimized extracorporeal circulation systems compared with conventional extracorporeal circulation.

نویسندگان

  • Adrian Bauer
  • Jan Schaarschmidt
  • Kyriakos Anastasiadis
  • Thierry Carrel
چکیده

We would like to refer to the recently published article by Aboud et al. [1] regarding negative venous line pressures and increased arterial air bubble count during minimized extracorporeal circulation (MECC). We think that there are several flaws in this paper. Recent studies have mainly focussed on gaseous microemboli (GME). Approaches are manifold, using arterial line filters, or additionally, venous bubble traps (VBTs) [2]. Roosenhoff et al. [3] showed a significant reduction of GMEs after the VBT. Kutschka et al. [4] showed a nearly complete reduction of GME post-arterial line filter. Perthel et al. [5] proved the relationship between reduced GME in the arterial line of MECC and a decreased emboli rate, demonstrated by transcranial ultrasound. In clinical terms, Anastasiadis et al. [6] proved that patients operated on MECC showed a clearly better postoperative neurocognitive course. After implementation of VBTs, our study group in Coswig focused on venous suction and took several measures: a small triple-stage venous cannula and use of a double purse-string suture to firmly fix the cannula. Furthermore, since 2007, in Coswig, we have been using a controlled negative-pressure approach. This, translated into clinical practice, means a continuous measuring of venous suction pressure with integrated regulation of arterial flow. There is also an ongoing study in Coswig focusing on GME regarding MECC vs conventional extracorporeal circulation. Moreover, the authors focused on one type of the MECC system. In fact, there are several different oxygenators that handle microbubbles in a different way. In the present study, the authors chose the worst possible combination, components which should most probably not be used for MECC perfusion. Most modern oxygenators have integrated bubble traps (Affinity Fusion) or an integrated arterial filter (Capiox FX). The best available MECC circuit may integrate these components, because they demonstrate practically no GME activity even at higher negative pressures. In general, every modern MECC circuit is negative pressure limited in terms of the operator being able to determine the maximal negative pressure— which is certainly never as high as −150 mmHg. Finally, MECC perfusions are always performed with a minimal positive right atrial pressure. However, the smaller the pump, the more negative will be the pressure. In the present study, the authors used the smallest available pump. In any case, in the era of the modern MECC systems and the routine use of real-time control of negative pressure to the venous line and VBT to all systems, we think that this paper is out-of-date. Moreover, the advice for further refinements of the systems to avoid adverse effects from increased arterial air bubbles is a rather misleading conclusion and may not refer to the systems, which are used in contemporary clinical practice. In summary, we would like to point out that despite the notable effort that the authors have made, the long-time interval between implementing their study and publishing their results suggests that advances in MECC technology and technique did not find enough consideration in the study design, and hence, we have to consider the entire work as not state-of-the-art.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effectiveness of low-prime cardiopulmonary bypass circuits at removing gaseous emboli.

During extracorporeal circulation, the patient's blood is siphoned into the extracorporeal circuit (ECC) by gravity or may be assisted kinetically or by vacuum. In all instances, negative pressure is generated in the venous line, which can cause entrainment of air into the ECC at the cannulation site. The typical ECC uses a venous reservoir, membrane oxygenator, and arterial line filter, which ...

متن کامل

Effect of closed minimized cardiopulmonary bypass on cerebral tissue oxygenation and microembolization.

OBJECTIVE Coronary artery bypass grafting with cardiopulmonary bypass carries a risk for neurologic complications because of cerebral hypoperfusion and microembolization. The basic goals of a novel closed minimized extracorporeal circulation are to prevent excessive hemodilution and to avoid blood-air interface. The aim of this prospective randomized study was to determine the effect of using t...

متن کامل

Tracheal Chondrosarcoma Excised With Extracorporeal Circulation

Introduction: Tracheal chondrosarcoma (TCS) is a rare malignancy, with only 19 cases described in the literature to date. Case presentation: Herein, we presented the third-largest TCS with such an airway compromise that neither orotracheal intubation nor jet ventilation or even tracheostomy was possible. So, extracorporeal circulation was needed to excise the tumor in a one-stage procedure. Th...

متن کامل

ECC Sources of Gaseous Microemboli

___________ _ We have tried to locate sources of gaseous microemboli during the ECC using a newly developed ultrasonic detector. The detector was calibrated with filters of known pore size and the recorder setting was kept constant at all times. We studied, at the oxygenator, the effect of low and high fill volume, refilling with or without air into the cardiotomy line, mechanical disturbance, ...

متن کامل

Comparison of gaseous microemboli counts in arterial, simultaneous and venous heat exchange with a hollow fiber membrane oxygenator.

Potential sources of gaseous microemboli during cardiopulmonary bypass are varied. However, it is known that membrane oxygenators generate fewer gaseous microemboli than bubble oxygenators and that bubblers cannot utilize arterial heat exchange without generating significant gaseous microemboli during rewarming. A membrane oxygenator utilizing simultaneous gas and heat exchange raises the con...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 46 1  شماره 

صفحات  -

تاریخ انتشار 2014