Cementless fixation of megaprostheses using a conical fluted stem in the treatment of bone tumours.
نویسندگان
چکیده
We reviewed 25 patients in whom a MUTARS megaprosthesis with a conical fluted stem had been implanted. There were three types of stem: a standard stem was used in 17 cases (three in the proximal femur, nine in the distal femur and five proximal tibia), a custom-made proximal femoral stem in four cases and a custom-made distal femoral stem in four cases. The mean age of the patients was 40.1 years (17 to 70) and the mean follow-up was for 2.5 years (0.9 to 7.4). At follow-up two patients had died from their disease: one was alive with disease and 22 were disease-free. One of 23 prostheses had been removed for infection and another revised to a cemented stem. The mean Musculoskeletal Tumor Society score was 24.9 (12 to 30) and the mean Karnofsky index was 82% (60% to 100%). There was no radiological evidence of loosening or subsidence. Stem stress shielding was seen in 11 patients and was marked in five of these. There were five complications, rupture of the extensor mechanism of the knee after extra-articular resection in two patients, deep venous thrombosis in one, septic loosening in one, and dislocation of the hip in one. The survival rate after seven years was 87% (95% confidence interval (CI) 83 to 91) for the patients and 95% (95% CI 91 to 99) for the megaprosthesis. A longer follow-up is needed to confirm these encouraging results.
منابع مشابه
Primary Rotational Stability of Various Megaprostheses in a Biomechanical Sawbone Model with Proximal Femoral Defects Extending to the Isthmus
PURPOSE Fixation of proximal femoral megaprostheses is achieved in the diaphyseal isthmus. We hypothesized that after extended bone resection including the proximal part of the isthmus a reduced length of fixation will affect the stability and fixation characteristics of these megaprostheses. The aim of this study was to analyze in a validated sawbone model with extended proximal femoral defect...
متن کاملTotal Hip Replacement Revision in a Single Brand Small Cementless Stem – Our Experience after the Findings of the National Joint Registry
Background: Cementless total hip replacement is the common THR performed in England, Wales, Northern Irelandand the Isle of Man. The Corail stem is the most popular cementless implant and has a ODEP 10A rating. Review ofits performance in the registry identified an increase rate of revision amongst the smaller stem sizes. However, claritywas not provided on the explanation for this finding. We ...
متن کاملThe Proximal and Distal Femoral Canal Geometry Influences Cementless Stem Anchorage and Revision Hip and Knee Implant Stability.
Although cementless revision arthroplasty of the hip has become the gold standard, revision arthroplasty of the distal femur is controversial. This study evaluated the anchoring principles of different femoral revision stem designs in extended bone defect situations, taking into account the anatomical conditions of the proximal and distal femur, and the resulting primary stability. Cementless p...
متن کاملLong-Term Follow-Up Results of a Second-Generation Cementless Femoral Prosthesis with a Collar and Straight Distal Fixation Channels
PURPOSE We evaluated the results of more than 10 years of follow-up of total hip arthroplasty using a second-generation cementless femoral prosthesis with a collar and straight distal fixation channels. MATERIALS AND METHODS One hundred five patients (129 hips) who underwent surgery between 1991 and 1996 for primary total hip arthroplasty using cementless straight distal fluted femoral stems ...
متن کاملSurvival and radiographic analysis of a glenoid component with a cementless fluted central peg.
BACKGROUND Aseptic loosening of glenoid components is a common problem associated with total shoulder arthroplasty and one cause for failure. A new cementless fluted glenoid component was developed and has shown excellent bony ingrowth in a canine model. HYPOTHESIS Clinical utilization of this cementless fluted pegged glenoid component in total shoulder arthroplasty would lower rates of radio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 89 8 شماره
صفحات -
تاریخ انتشار 2007