Analysis of resistance to gas flow in nine adult ventilator circuits.
نویسندگان
چکیده
We measured the resistance in nine complete ventilator circuits, partial circuits and 7, 8, and 9 mm ID endotracheal tubes at flow rates of 20 to 120 liters per minute. We found a statistically significant (p less than 0.01) increase in resistive pressure with increases in flow rate, as the diameter of the ETT decreased, and as each component of the ventilator circuit was added to the ETT. There was a curvilinear increase in resistive pressure to increase in flow rate. However, when resistances were computed, the Bennett cascade "circuit" created higher resistance at 20 lpm than at flow rates up to 120 lpm. The Bennett cascade humidifier added the greatest resistive pressure, 3.5 to 8.5 cm H2O, the Engstrom Edith, 0.5 to 6.5 cm H2O, and the Conchapak added the least, 0.0 to 2.5 cm H2O at flow rates of 20 to 120 lpm. After all the components of the ventilator circuit were attached to the ETTs, there was approximately a 97 to 450 percent increase in resistive pressure compared to the resistive pressure created by the ETTs alone.
منابع مشابه
Measuring exhaled volume with continuous positive airway pressure and intermittent mandatory ventilation. Techniques and rationale.
When patients breathe spontaneously through a ventilator circuit, a fall in airway pressure during the inspiratory cycle may increase inspiratory effort. A system of delivery which incorporates a distensible reservoir bag and delivers a constant flow of gas that is two or three times the patient's minute volume will prevent a significant drop in inspiratory airway pressure. Unfortunately, the c...
متن کاملEffect of eight weeks high intensity circuits resistance training and interval and continues ginger supplementation on the hemorheological factors of obese females
Introduction and purpose: Obesity is the effectiveness factor of blood vessels. The purpose of this study was to investigate the effect of eight weeks high intensity circuits’ resistance training and interval and continues of ginger supplementation on the levels of fibrinogen, platelets, hematocrit and hemoglobin of obese women. Materials and methods: In order to, 44 obese women (age: 30.11±6.4...
متن کاملAmine Based CO2 Absorption in Membrane Contactor Using Polyvinyl Pyrrolidone-modified Polysulfone Flat Sheet Membrane: Experimental Study and Mass Transfer Resistance Analysis
Membrane contactor using amine based absorbents is an efficient technology for CO2 separation from gaseous mixtures. A novel porous polysulfone (PSF) flat membrane was prepared via non-solvent phase inversion method. The PSF membrane was modified by adding polyvinyl pyrrolidone (PVP) to the dope solution. The fabricated membrane was used in the serpentine flow field contactor module for CO2 abs...
متن کاملSteady Flow Analysis and Modeling of the Gas Distribution Network Using the Electrical Analogy (RESEARCH NOTE)
The mathematical modeling of a gas network is a powerful tool in order to identify the behavior of system under the different conditions. The modeling can be performed both for the steady state and unsteady state conditions. It is possible to use the fluid flow basic governing equations or the electrical analogy concept for developing the model. The second approach provides a simpler and more r...
متن کاملInterim study: Comparison of safety and efficacy of Levofloxacin plus Colistin regimen with Levofloxacin plus high dose Ampicillin/Sulbactam infusion in treatment of Ventilator-Associated Pneumonia due to multi drug resistant Acinetobacte
Due to the emerging antibiotic resistance of Acinetobacter, which is the leading cause of ventilator-associated pneumonia (VAP) in critically ill patients, there is an urgent need for studies comparing various antibiotic regimens for its treatment. In this single blinded randomized clinical trial, adult patients with VAP due to multi drug resistant Acinetobacter (MDRA), were randomly assigned ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Chest
دوره 96 6 شماره
صفحات -
تاریخ انتشار 1989