An assessment of the “map-potential” and “beam-swinging” techniques for measuring the ionospheric convection pattern using data from the SuperDARN radars

نویسندگان

  • G. Provan
  • T. K. Yeoman
  • S. E. Milan
  • J. M. Ruohoniemi
چکیده

The SuperDARN HF coherent scatter radars (Greenwald et al., 1995) provide line-of-sight (l-o-s) velocity measurements of ionospheric convection flow over the polar regions of the northern and southern hemispheres. A number of techniques have been developed in order to obtain 2-D plasma flow vectors from these l-o-s observations. This study entails a comparison of the ionospheric flow vectors derived using the “map-potential”, and “beam-swinging” techniques with the vectors derived using the “merging” technique. The merging technique is assumed to be the most accurate method of deriving local flow vectors from l-o-s velocities. We can conclude that the map-potential model is significantly more successful than the beam-swinging technique at estimating both the magnitude and the direction of the largescale ionospheric convection flow vectors. The quality of the fit is dependent on time of day, with vectors observed at low latitudes in the dawn sector agreeing most closely with the merged vector flow pattern.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of mixed scatter on SuperDARN convection maps

The SuperDARN radars map high-latitude ionospheric plasma drift velocities by measuring the Doppler frequency shift of HF signals scattered by decameter electron density irregularities. In many cases the ionospheric returns are contaminated by strong scatter from the ground or sea surface. In this paper we develop and test a two-component fitting algorithm to separate ionospheric and surface sc...

متن کامل

Comparison of Ionospheric Electric Currents and Plasma Convection Patterns Observed during Substorms

The effect of magnetospheric substorms on the global ionospheric convection pattern is widely debated. Discussed here, is a study made of ionospheric electric currents, co-incident with plasma convection at the time of substorm onset, using the HF radars of the Super Dual Auroral Radar Network (SuperDARN), and the global array of ground magnetometers. Preliminary results are presented, which ut...

متن کامل

Electrostatic potential patterns in the high-latitude ionosphere constrained by SuperDARN measurements

The recent addition of two radars to the existing network of six Super Dual Auroral Radar Network (SuperDARN) HF radars in the Northern Hemisphere has significantly extended the area in the high latitude where measurements of convecting ionospheric plasma are made. We show that the distribution of the electrostatic potential ß associated with the "E x B" drift of ionospheric plasma can be relia...

متن کامل

Elevation Angle Determination for SuperDARN HF Radar Layouts

The international scientific radars known as the Super Dual Auroral Radar Network (SuperDARN) are designed to primarily measure plasma convection at ionospheric altitudes over a large region of the northern and southern hemispheres. SuperDARN radars are equipped with a secondary interferometry array that is used to measure the elevation angle (α) of signals. These values of α have been used in ...

متن کامل

The dayside ultraviolet aurora and convection responses to a southward turning of the interplanetary magnetic field

We examine the large-scale ultraviolet aurora and convection responses to a series of flux transfer events that immediately followed a sharp and isolated southward turning of the IMF. During the interval of interest, SuperDARN was monitoring the plasma convection in the dayside northern ionosphere, while the VIS Earth Camera and the Far Ultraviolet Imager (UVI) were monitoring the northern hemi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001