Comparative evaluation of the stability of two different dental implant designs and surgical protocols—a pilot study
نویسندگان
چکیده
BACKGROUND The purpose of this study was to compare a parallel wall design implant to a tapered apex design implant when placed in the posterior maxilla using two different surgical protocols. METHODS Twenty-seven patients (30 implants) were divided into three groups. All implants were 4 mm wide in diameter and 8 mm long. Group A received 10 tapered implants (OSPTX) (Astra Tech OsseoSpeed TX™) using the soft bone surgical protocol (TXSoft). Group B received 10 tapered implants (OSPTX) (AstraTech OsseoSpeedTX™) using the standard surgical protocol (TXStd). Group C received 10 parallel wall implants (OSP) (AstraTech OsseoSpeed™) using the standard surgical protocol (OStd). All implants were placed in the posterior maxilla in areas with a minimum of 8-mm crestal bone height. Resonance frequency measurements (implant stability quotient (ISQ)) and torque values were recorded to determine initial implant stability. All implants were uncovered 6 weeks after placement and restored with a functionally loaded resin provisional screw-retained crown. Resonance frequency measurements were recorded at the time of implant placement, at 6 weeks and 6 and 12 months. Twelve months after implant placement, the stability of the implants was recorded and the final restorations were placed using custom CAD/CAM fabricated abutments and cement-retained PFM DSIGN porcelain crowns. After implant restoration, bone levels were measured at 6 and 12 months with standardized radiographs. RESULTS Radiographic mean bone loss was less than 0.5 mm in all groups, with no statistically significant differences between the groups. Implant survival rate at 1 year was 93.3%, with 2/30 implants failing to integrate prior to functional loading at 6 weeks. No statistically significant difference was found between ISQ measurements between the three groups at all time intervals measured. Strong positive correlations were found between overall bone loss at 6 months and insertion torque at time of placement. A very weak correlation was found between insertion torque and ISQ values at time of implant placement. CONCLUSIONS Survival and stability of OSPTX and OSP implants is comparable. Osteotomy preparation by either standard or soft bone surgical protocol presented no significant effect on implant survival and stability for the specific implant designs.
منابع مشابه
Evaluation of Stability in Short Implants Compared to Standard Implants using Periotest ®: A Pilot Study
Introduction: Among different non-invasive approaches for determining the stability of the implant within the bone is to use a dynamic device called Periotest®.It is designed to provide objective measurement of tooth mobility. The aim of the present study is to evaluate the stress transfer and stability in short and standard dental implants using Periotest®</sup...
متن کاملImmediate loading in dental implants ( A literature review )
Immediate loading in dental implants ( A literature review ) Dr. Seyedan K.,1 Dr. Hafezeqoran A.,2 Dr. Sazgara H.3 1Assistant Professor, Department of Prosthodentists,Dental School Shahid Beheshti University of Medical Sciences,Tehran, Iran.2Dentist, Post Graduate Student, Department of Prosthodontics, Dental School, Shahid Beheshti University of Medical Sciences, Tehran-Iran.3Associate Profess...
متن کاملComparison of the Effect of Ball and Bar Attachment Designs on Retention and Stability of Mandibular Implant-Supported Overdentures
Objectives: The present study evaluated the effect of bar and ball attachment designs on retention and stability of a mandibular overdenture supported by four implants. Methods: An edentulous mandibular acrylic resin model with four implants in the anterior part of the ridge (A, B, D and E) was fabricated. A metal framework simulating the overdenture was also fabricated. Totally, 30...
متن کاملStress Distribution in Natural Tooth and Implant Supported Removable Partial Denture with Different Attachment Types: A Photoelastic Analysis
Background and Aim: Different attachment designs have been developed to connect implant to natural teeth in partial dentures; however, adequate studies have not been performed to determine stress distribution patterns in these designs. The present study aimed to assess stress distribution patterns in natural tooth and implant supported removable partial denture with different attachment designs...
متن کاملComparative study of two different implants with hexogonal connection on the amount of bacteria accumulated at the implant platform site: An in-vivo study
Background and Aims: Nowadays, the best choice for replacing missing teeth are dental implants, however, failure is not unexpected. One of the factors that plays an important role in the implant failure is bacterial microleakage which could cause biological complication. The aim of this study was to compare the bacterial microleakage between the two types of implants. Materials and Methods:...