Electrical Conductivity of Molten LaBr3 and LaBr3–MBr Binary Mixtures
نویسنده
چکیده
Institute of Inorganic Chemistry and Metallurgy of Rare Elements, Wroclaw University of Technology, Wybrzeze Wyspianskiego 27, 50-370 Wroclaw, Poland a Faculty of Natural Science, Department of Chemistry, University of Novi Sad, Trg D. Obradovica 3, 21000 Novi Sad, Serbia & Montenegro b Ecole Polytechnique, Mecanique Energetique, Technopole de Chateau Gombert, 5 rue Enrico Fermi, 13453 Marseille Cedex 13, France
منابع مشابه
Structure and Dynamic Properties of Molten Lanthanum Tribromide
The structure of molten LaBr3 was investigated by X-ray diffraction and molecular dynamics simulations. It was found that the short range structure of molten LaBr3 is very similar to that of molten LaCl3, except for some structural features such as interionic distances based on the difference of anion sizes. In the MD simulation, the shear viscosity of molten LaBr3 was estimated from the struct...
متن کاملInvestigation of LaBr3: Ce and LaCl3: Ce scintillators for spect imaging
This study aims to investigate the potential use of LaBr3:Ce and LaCl3:Ce materials in SPECT imaging. GATE Monte Carlo simulations of single-head gamma camera and a Tc point source were performed to evaluate the energy spectra, modulation transfer function (MTF) and detection efficiency. A range of Ce concentrations (0.5, 5, 10 and 15)% of LaBr3:Ce and LaCl3:Ce crystals was simulated in conjunc...
متن کاملImage quality assessment of LaBr3-based whole-body 3D PET scanners: a Monte Carlo evaluation.
The main thrust for this work is the investigation and design of a whole-body PET scanner based on new lanthanum bromide scintillators. We use Monte Carlo simulations to generate data for a 3D PET scanner based on LaBr3 detectors, and to assess the count-rate capability and the reconstructed image quality of phantoms with hot and cold spheres using contrast and noise parameters. Previously we h...
متن کاملLanthanum Bromide Scintillation Detector for Gamma Spectrometry Applied in Internal Radioactive Contamination Measurements
Apariţia de noi tipuri de detectori cu scintilatori anorganici LaBr3(Ce) şi LaCl3(Ce), a generat necesitatea testării lor pentru diferite aplicaţii. Ca o alternativă a detectorului NaI(Tl), utilizat, în mod tradiţional, în sistemele gama de monitorizare a I-131, în tiroidă, a fost considerat pentru caracterizare, un detector LaBr3(Ce), de dimensiuni 1.5“ x 1.5”. Rezultatele au fost evaluate, ur...
متن کاملThe Electric Conductivity of Molten HgI2-HgBr2 and Hgl2-Sbl3 Binary Mixtures
The specific electric conductivity of molten HgI2-HgBr2 and Hgl2-Sbl3 binary mixtures was measured as a function of composition and temperature in the ranges 220 — 540 °C and 180 to 540 °C, respectively. In the HgI2-HgBr2 system negative deviations from additivity are found in mixtures rich in HgBr2, and positive ones in those rich in Hgl2 . The positive deviations are more pronounced at higher...
متن کامل