RETINAL DISORDERS Quantitative analysis of central visual field defects in macular edema using three-dimensional computer-automated threshold Amsler grid testing
نویسندگان
چکیده
Purpose To evaluate the central visual field (CVF) with specialized Amsler grid testing methods that include contrast sensitivity evaluation, in an attempt to detect abnormalities not identified with standard methods and to define new patterns of CVF deficits in two different diseases. Methods 3D computer-automated threshold Amsler grid testing (3D-CTAG) was performed at five levels of contrast in one eye of 37 patients with diabetic macular edema (DME, n=16) and exudative age-related macular degeneration (AMD, n=21). Results 3D-CTAG abnormalities were detected in six patients (16%) who had no abnormalities with conventional Amsler grid testing. DME patients had more foci of CVF deficits (3.56±2.92 defects/eye), than AMD patients (1.24± 0.89 defects/eye; P<0.0002). The shape of the 3D-CTAG abnormality in DME was an inverted cone, while the deficits in AMD were always cylindrical. All eyes showed significant increases in CVF deficit surface area at minimum contrast levels when compared to maximum contrast (295% greater with DME, P<0.02 and 150% greater with AMD, P<0.03). Conclusion 3D-CTAG detected CVF abnormalities not identified with conventional Amsler grid testing in 16% of subjects. Low-contrast conditions elicited a larger defect in both DME (3-fold) and AMD (1.5-fold). DME and AMD have unique 3D-CTAG profiles, enabling diagnostic discrimination. Measuring CVF defects with 3D-CTAG can quantitatively index disease severity and may be useful in longitudinal studies of the natural history of disease, as well as providing a quantitative outcome measure of the response to therapy.
منابع مشابه
Distinguishing wet from dry age-related macular degeneration using three-dimensional computer-automated threshold Amsler grid testing.
BACKGROUND/AIMS With the increased efficacy of current therapy for wet age-related macular degeneration (AMD), better ways to detect wet AMD are needed. This study was designed to test the ability of three-dimensional contrast threshold Amsler grid (3D-CTAG) testing to distinguish wet AMD from dry AMD. METHODS Conventional paper Amsler grid and 3D-CTAG tests were performed in 90 eyes: 63 with...
متن کاملScotomas of age-related macular degeneration detected and characterized by means of a novel three-dimensional computer-automated visual field test.
PURPOSE We used the recently devised three-dimensional computer-based threshold Amsler grid test to acquire and identify typical patterns of visual field defects (scotomas) caused by age-related macular degeneration (AMD). METHODS Patients with AMD traced on a computer touch screen the borders of those areas on an Amsler grid that were missing from their field of vision. Scotomas were repeate...
متن کاملNovel 3 D Computerized Threshold Amsler Grid Test
Purpose: To introduce a novel 3D computerized threshold Amsler grid test, developed by Fink and Sadun, that allows for a novel characterization of the structure of visual field defects in three dimensions (see http://www.wfbabcom5.com/wf335.htm). Methods: With one eye covered, patients are placed in front of a computer monitor displaying an Amsler grid. While focusing on a varying central fixat...
متن کاملNovel 3D computer-automated threshold Amsler grid visual field testing of scotomas in patients with glaucoma.
PURPOSE Three-dimensional (3D) computer-automated threshold Amsler grid testing was used to identify and characterize scotomas typical of glaucoma. METHODS The 3D test exhibits a grid on a computer screen at a preselected grayscale and angular resolution, and allows patients to trace those areas on the grid that are missing in their visual field using a touch screen. Eleven eyes in patients w...
متن کاملThree-dimensional computer-automated threshold Amsler grid test.
We describe a novel method for testing a visual field that employs a computer monitor with displays of varying contrast that permits unprecedented resolution and characterization of the structure of scotomas in three dimensions. Patients are placed in front of a touch-sensitive computer screen at a fixed distance. With one eye covered, they focus on a central fixation marker and trace with thei...
متن کامل