Echo-Time and Field Strength Dependence of BOLD Reactivity in Veins and Parenchyma Using Flow-Normalized Hypercapnic Manipulation
نویسندگان
چکیده
While the BOLD (Blood Oxygenation Level Dependent) contrast mechanism has demonstrated excellent sensitivity to neuronal activation, its specificity with regards to differentiating vascular and parenchymal responses has been an area of ongoing concern. By inducing a global increase in Cerebral Blood Flow (CBF), we examined the effect of magnetic field strength and echo-time (TE) on the gradient-echo BOLD response in areas of cortical gray matter and in resolvable veins. In order to define a quantitative index of BOLD reactivity, we measured the percent BOLD response per unit fractional change in global gray matter CBF induced by inhaling carbon dioxide (CO(2)). By normalizing the BOLD response to the underlying CBF change and determining the BOLD response as a function of TE, we calculated the change in R(2)(*) (ΔR(2)(*)) per unit fractional flow change; the Flow Relaxation Coefficient, (FRC) for 3T and 1.5T in parenchymal and large vein compartments. The FRC in parenchymal voxels was 1.76±0.54 fold higher at 3T than at 1.5T and was 2.96±0.66 and 3.12±0.76 fold higher for veins than parenchyma at 1.5T and 3T respectively, showing a quantitative measure of the increase in specificity to parenchymal sources at 3T compared to 1.5T. Additionally, the results allow optimization of the TE to prioritize either maximum parenchymal BOLD response or maximum parenchymal specificity. Parenchymal signals peaked at TE values of 62.0±11.5 ms and 41.5±7.5 ms for 1.5T and 3T, respectively, while the response in the major veins peaked at shorter TE values; 41.0±6.9 ms and 21.5±1.0 ms for 1.5T and 3T. These experiments showed that at 3T, the BOLD CNR in parenchymal voxels exceeded that of 1.5T by a factor of 1.9±0.4 at the optimal TE for each field.
منابع مشابه
Hypercapnic normalization of BOLD fMRI: comparison across field strengths and pulse sequences.
The blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) signal response to neural stimulation is influenced by many factors that are unrelated to the stimulus. These factors are physiological, such as the resting venous cerebral blood volume (CBV(v)) and vessel size, as well as experimental, such as pulse sequence and static magnetic field strength (B(0)). Thus...
متن کاملInter-subject variability in hypercapnic normalization of the BOLD fMRI response
In the application of hypercapnic normalization to functional magnetic resonance imaging (fMRI) studies, the blood oxygenation level dependent (BOLD) response to a functional stimulus is typically divided by the BOLD response to a hypercapnic challenge. While some prior studies have shown that hypercapnic normalization can reduce inter-subject BOLD variability, other studies have found an incre...
متن کاملComparison of the dependence of blood R2 and R2* on oxygen saturation at 1.5 and 4.7 Tesla.
Gradient-echo (GRE) blood oxygen level-dependent (BOLD) effects have both intra- and extravascular contributions. To better understand the intravascular contribution in quantitative terms, the spin-echo (SE) and GRE transverse relaxation rates, R(2) and R(2)(*), of isolated blood were measured as a function of oxygenation in a perfusion system. Over the normal oxygenation saturation range of bl...
متن کاملSource of nonlinearity in echo-time-dependent BOLD fMRI.
Stimulation-induced changes in transverse relaxation rates can provide important insight into underlying physiological changes in blood oxygenation level-dependent (BOLD) contrast. It is often assumed that BOLD fractional signal change (DeltaS/S) is linearly dependent on echo time (TE). This relationship was evaluated at 9.4 T during visual stimulation in cats with gradient-echo (GE) and spin-e...
متن کاملEffect of Phase-Encoding Reduction on Geometric Distortion and BOLD Signal Changes in fMRI
Introduction Echo-planar imaging (EPI) is a group of fast data acquisition methods commonly used in fMRI studies. It acquires multiple image lines in k-space after a single excitation, which leads to a very short scan time. A well-known problem with EPI is that it is more sensitive to distortions due to the used encoding scheme. Source of distortion is inhomogeneity in the static B0 field that ...