Preoperative ⁹⁹mTc-sestamibi scintigraphy in patients with primary hyperparathyroidism and concomitant nodular goiter: comparison of SPECT-CT, SPECT, and planar imaging.
نویسندگان
چکیده
BACKGROUND Investigations using a hybrid single photon emission computed tomography/computed tomography (SPECT-CT) scanning technique have been carried out in limited studies and have shown mixed results. However, the assessment of this technique for the detection of parathyroid adenoma in patients with a nodular goiter was performed in only one study with a small sample size. The aim of this prospective study was to assess the role of 99mTc-sestamibi parathyroid SPECT-CT scans for localization of parathyroid adenomas with a concomitant nodular goiter using 99mTc-methoxyisobutyl isonitrile (MIBI) scintigraphy and to compare it with SPECT and planar imaging. METHODS This study was conducted on 48 patients with primary hyperparathyroidism and nodular goiter, who were candidates for parathyroid surgery and had been referred for parathyroid scintigraphy. The patients underwent an early set of planar 99mTc-MIBI scanning procedures first, followed by SPECT and CT scannings, and finally a delayed set of planar 99mTc-MIBI scannings. Sensitivity, specificity, negative and positive predictive values, and accuracy were determined on a per-parathyroid-gland basis for each scanning method, as defined by histology and follow-up. RESULTS The surgery was successful in 48 out of 50 patients with primary hyperparathyroidism concomitant with thyroid nodularity, and data were completed for 80 sites in 48 patients. The accuracy of SPECT-CT in correctly identifying a parathyroid adenoma was 85.00, versus 75.00% for SPECT (P=0.01, significant). The sensitivity and specificity for SPECT-CT were 77.55 and 96.77%, respectively, versus 67.34 and 87.09%, respectively, for SPECT (P=0.12 and 0.12, not significant). There were nine sites that showed better localization on SPECT-CT scans relative to SPECT images, of which five sites were located in the ectopic regions. CONCLUSION The results of our study indicate that SPECT-CT is more accurate than sestamibi planar imaging and SPECT for the preoperative identification of parathyroid lesions in patients with primary hyperparathyroidism concomitant with thyroid nodularity. Also, we would recommend the use of SPECT-CT for a workup of all patients with ectopic glands who are scheduled for minimally invasive parathyroid surgery.
منابع مشابه
SPECT-CT fusion in the diagnosis of hyperparathyroidism
Objective(s): In this study, we aimed to analyze the relationship between the diagnostic ability of fused single photon emission computed tomography/computed tomography (SPECT/CT) images in localization of parathyroid lesions and the size of adenomas or hyperplastic glands. Methods: Five patients with primary hyperparathyroidism (PHPT) and 4 patients with secondary hyperparathyroidism (SHPT) we...
متن کامل99mTc-MIBI SPECT/CT imaging contribution in the diagnosis of patients with hyperparathyroidism
Introduction: Hyperparathyroidism is presented with increased parathyroid hormone (PTH) secretion due to hyperfunctioning of one or more of the four parathyroid glands. Primary hyperparathyroidism (p-HPT) can be due to parathyroid adenoma, hyperplasia or carcinoma of the parathyroid gland. Secondary hyperparathyroidism (s-HPT) is usually a response to hypocalcaemia and consecut...
متن کاملPreoperative technetium Tc 99m sestamibi SPECT imaging in the management of primary hyperparathyroidism in patients with concomitant multinodular goiter.
HYPOTHESIS Preoperative parathyroid and thyroid imaging using technetium Tc 99m sestamibi scintigraphy-single-photon emission computed tomography (Tc 99m MIBI SPECT) and technetium Tc 99m sodium pertechnetate, respectively, in patients with parathyroid adenomas and concomitant multinodular goiters enables the selection of those suitable for minimally invasive radio-guided surgery. DESIGN One ...
متن کاملComparison of SPECT/CT, SPECT, and planar imaging with single- and dual-phase (99m)Tc-sestamibi parathyroid scintigraphy.
UNLABELLED Various methodologies for (99m)Tc-sestamibi parathyroid scintigraphy are in clinical use. There are few direct comparisons between the different methods and even less evidence supporting the superiority of one over another. Some reports suggest that SPECT is superior to planar imaging. The addition of CT to SPECT may further improve parathyroid adenoma localization. The purpose of ou...
متن کاملTc-MIBI PINHOLE SPECT IN PRIMARY HYPERPARATHYROIDISM: COMPARISON WITH CONVENTIONAL SPECT, PLANAR SCINTIGRAPHY AND ULTRASONOGRAPHY
Purpose A pinhole collimator is routinely used to increase the resolution of scintigraphy. This prospective study was conducted to determine the interest of Tc-MIBI pinhole SPECT for the preoperative localization of parathyroid lesions in primary hyperparathyroidism. Methods All patients underwent a neck US, TcO4 and Tc-MIBI planar images, and two consecutive SPECT with a parallel (C-SPECT) and...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nuclear medicine communications
دوره 33 10 شماره
صفحات -
تاریخ انتشار 2012