A new, safe and convenient 5-L dual-chamber container for automated peritoneal dialysis.

نویسندگان

  • Johan V Povlsen
  • Michael Koch
  • Bo Eklund
  • Olof Heimburger
  • Synke van der Heyden
  • Audrey M Hutchcraft
  • Bruno Remacle
  • Peter Rutherford
  • Ira D Davis
چکیده

BACKGROUND Automated peritoneal dialysis (APD) provides the opportunity for home-based dialysis, enabling the patient to optimize their lifestyle by maintaining their normal daily routine. Use of a larger bag size and biocompatible solution is desirable. In an effort to further improve patient convenience and reduce the probability of infusing only the buffer contents from the outflow chamber, we designed a 5-L dual-chamber container system with a dual-seal system consisting of a long seal between the dextrose chamber and buffer chambers and a short SafetyMoon™ seal between the buffer chamber and container outflow connector. METHODS The safety and effectiveness of this new container system was assessed in a non-interventional, prospective, open-label, multi-centre, uncontrolled, Baxter-sponsored post-authorization safety study in 249 patients from 7 countries in Europe. RESULTS No mis-infusion events were noted throughout the study where 68 519 Physioneal™ 5-L bags in Clear-Flex™ were used for an average (SD) of 4.3 (1.9) months per patient. Overall, the percentage of patients and/or care providers rating the 5-L bag preparation as very easy or easy at baseline (0-8 weeks), 9-16, 17-24 and 25-32 weeks ranged from 94 to 97%. Assuming a Poisson distribution for the bag count data, the estimated change in number of bicarbonate/lactate dialysis fluid bags (5 or 2.5 L) as a percent of prior bag use was -36%, while the estimated change in number of bags for ALL solutions as a percent of prior bag use was -31%. The predominant reasons given by the investigators for prescribing 5-L PD solutions at study onset were biocompatibility, easier and convenient for their patients to use, physiological pH and less bag connections. None of the 92 serious adverse events were suspected to be related to the Physioneal 5-L PD solution. CONCLUSIONS Use of a larger, Physioneal 5-L bag mitigates the concern regarding the possibility of mis-infusing the buffer chamber solution, is convenient to use by the patient/health care provider and is associated with more than a 30% reduction in the weekly number of dialysis solution bags required per patient for their APD therapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Developing a Device for Automated Peritoneal Dialysis

Background: Peritoneal dialysis (PD) is an efficient alternative for hemodialysis. Removal of waste metabolites and excess water from the blood circulation are the two main tasks done during dialysis. These are done by using a filter; in PD, the naturally semi-permeable peritoneal membrane acts as the filter. Automated PD machines control intelligently the operations to enhance the efficiency a...

متن کامل

Effectiveness of Automated Peritoneal Dialysis Compared to Outpatient Procedure: A Systematic Review and Meta-analysis Study

Introduction: The growing trend of renal failure has focused clinical therapy on the cost-effective alternatives such as peritoneal dialysis. Therefore, the present study has investigated the effectiveness of two methods of continuous and automatic peritoneal dialysis in the patients with end stage renal disease. Methods: This study was conducted in the form of a systematic review. Advanced se...

متن کامل

بقا و عوارض کاتترهای دیالیز صفاقی: معرفی یک روش لاپاروسکوپی با بی‌حسی موضعی

Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 !mso]> st1":*{behavior:url(#ieooui) } /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal" mso-tst...

متن کامل

Automated peritoneal dialysis with 'on-line'-prepared bicarbonate-buffered dialysate: technique and first clinical experiences.

BACKGROUND Automated peritoneal dialysis (APD) has the possibility of increasing the dialysis efficacy by using higher fill volumes, frequent dialysate exchanges, and tidal techniques. It is then possible to treat patients adequately without residual renal function. The drawbacks of the required high amounts of dialysis solution of up to 30 litres per session are the high costs of lactate-based...

متن کامل

Cost Function Modelling for Semi-automated SC, RTG and Automated and Semi-automated RMG Container Yard Operating Systems

This study analyses the concept of cost functions for semi-automated Straddle Carrier (SC), Rubber Tyred Gantry (RTG) and automated Rail Mounted Gantry (RMG) container yard operating cranes. It develops a generic cost based model for a pair-wise comparison, analysis and evaluation of economic efficiency and effectiveness of container yard equipment to be used for decision-making by terminal pla...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association

دوره 26 1  شماره 

صفحات  -

تاریخ انتشار 2011