Design Considerations for Medical Proton Accelerators
نویسندگان
چکیده
The design requirements for current heavy-particle accelerators operated within a hospital to deliver radiation therapy must satisfy both clinical and research needs. Advances in dedicated beam delivery systems for clinical utilization and biological studies add requirements that previous accelerators did not have. Eight years experience using the Loma Linda University proton facility has emphasized that the most important requirements are safety, reliability, beam stability, low energy consumption, and efficiency of beam delivery to the treatment rooms. In the future, raster scanning techniques will add further demands on the control of beam energy, intensity, and position stability. Rapid and precise flexibility in changing beam parameters is essential for satisfying clinical needs; electronic rather than mechanical control is clearly preferable for clinical use. Biological research increases the need to expand the margins of some clinical requirements, such as beam size, intensity, and energy ranges. Both clinical and research activities require a totally integrated control system, beginning with the ion source and continuing through the accelerator and switchyard to multiple rooms and each beam delivery system therein. Accordingly, designing the clinical accelerator requires a highly orchestrated design effort, involving the entire facility. Detailed design requirements addressing these issues will be presented.
منابع مشابه
Some Considerations on the Choice of Frequency and Geometrical Beta in High Power Proton Linacs in the Context of Higher Order Modes
Several high power superconducting (SC) proton linear accelerators are currently in the design stage around the world, such as for example the European Spallation Source (ESS) in Lund, Project X at Fermilab, the European ADS demonstrator MYRRAH in Mol, and the Superconducting Proton linac (SPL) at CERN. In this contribution, the influence of Higher Order Modes (HOMs) in elliptical SC cavities i...
متن کاملBenchmark Calculations of Neutron Production and Induced Radioactivity for a Proton and a Carbon Therapy Accelerator*
This study intends to predict the scope of neutron production and induced radioactivity for two therapy accelerators in Taiwan: 235 MeV proton and 400 MeV/A carbon ion accelerators. For radiation safety concern, much effort has been put into associated benchmark calculations to ensure the quality of predictions. Two Monte Carlo codes FLUKA and MCNPX were applied to calculate the neutron yield f...
متن کاملOptimization of Medical Accelerators*
The Optimization of Medical Accelerators (OMA) is the aim of a new European training network. OMA joins universities, research centers and clinical facilities with industry partners to address the challenges in treatment facility design and optimization, numerical simulations for advanced treatment schemes, and beam imaging and treatment monitoring. Projects include: compact accelerators for pr...
متن کاملCalculation of Neutron Dose Ratio of Heart, Lung and Liver due to breast cancer Proton Therapy using MCNPX code
Introduction: The proton beam produced in particle accelerators has an appropriate therapeutic potential. In this research, proton therapy of breast cancer is simulated using the MCNPX code in a MIRD phantom, also the contribution of scattered neutron dose during the proton therapy were calculated for the Heart, Lung and Liver. Materials and Methods: For si...
متن کاملDesigning an approprate solenoid and magnetic field for the HZDR laser-driven beamline
Nowadays, due to the high costs and large dimensions of the conventional proton accelerators, other optimal methods for producing the proton beam have been studied. Using of Laser-driven proton accelerators is one of the important and new methods. In laser-driven ion acceleration, a highly ultra-intense laser pulse interacts with solid density targets and will create a plasma media that will ac...