Reduced Radiation Exposure for Face Transplant Surgical Planning Computed Tomography Angiography
نویسندگان
چکیده
OBJECTIVE To test the hypothesis that wide area detector face transplant surgical planning CT angiograms with simulated lower radiation dose and iterative reconstruction (AIDR3D) are comparable in image quality to those with standard tube current and filtered back projection (FBP) reconstruction. MATERIALS AND METHODS The sinograms from 320-detector row CT angiography of four clinical candidates for face transplantation were processed utilizing standard FBP, FBP with simulated 75, 62, and 50% tube current, and AIDR3D with corresponding dose reduction. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured at muscle, fat, artery, and vein. Image quality for each reconstruction strategy was assessed by two independent readers using a 4-point scale. RESULTS Compared to FBP, the median SNR and CNR for AIDR3D images were higher at all sites for all 4 different tube currents. The AIDR3D with simulated 50% tube current achieved comparable SNR and CNR to FBP with standard dose (median muscle SNR: 5.77 vs. 6.23; fat SNR: 6.40 vs. 5.75; artery SNR: 43.8 vs. 45.0; vein SNR: 54.9 vs. 55.7; artery CNR: 38.1 vs. 38.6; vein CNR: 49.0 vs. 48.7; all p-values >0.19). The interobserver agreement in the image quality score was good (weighted κ = 0.7). The overall score and the scores for smaller arteries were significantly lower when FBP with 50% dose reduction was used. The AIDR3D reconstruction images with 4 different simulated doses achieved a mean score ranging from 3.68 to 3.82 that were comparable to the scores from images reconstructed using FBP with original dose (3.68-3.77). CONCLUSIONS Simulated radiation dose reduction applied to clinical CT angiography for face transplant planning suggests that AIDR3D allows for a 50% reduction in radiation dose, as compared to FBP, while preserving image quality.
منابع مشابه
Assessment of radiation-induced cancer risk to patients undergoing computed tomography angiography scans
Background: Computed tomography angiography (CTA) scan is a suitable imaging technique to evaluate the blood vessels. However, one major disadvantage is the potential risk of cancer related to ionizing radiation exposure during the procedures. The aim of this investigation was to estimate the risk of exposure induced cancer death (REID) values for some common computed tomography angiography (CT...
متن کاملThe radiation exposure of Computed Tomographic Angiography (CTA) in DIEP flap planning: low dose but high impact.
Table 1 Radiation dose (and comparative background radiation exposure) associated with various imaging techniques, including plain-film x-rays, computed tomography (CT) scans and computed tomography angiography (CTA) scans. Exposure calculated with ImPACT CT Patient Dosimetry Calculator (Version 0.99w, ImPACT, St. George’s The radiation exposure of Computed Tomographic Angiography (CTA) in DIEP...
متن کاملClinical applications of virtual, non-contrast head images derived from dual-source, dual-energy cerebrovascular computed tomography angiography
Background: This study set out to evaluate the utility of cerebrovascular virtual non-contrast (VNC) scans. Materials and Methods: Conventional non-contrast (CNC) and dual-energy computed tomography angiography (DE-CTA) head scans were conducted on 100 subjects, of which 46 were normal, 15 had parenchymal hematomas of the brain, 13 had ischemic infarction, 22 had tumors, and 4 had calcified les...
متن کاملNoninvasive Vascular Images for Face Transplant Surgical Planning
OBJECTIVE Face transplantation replaces substantial defects with anatomically identical donor tissues; preoperative vascular assessment relies on noninvasive imaging to separate and characterize the external carotid vessels and branches. The objective is to describe and illustrate vascular considerations for face transplantation candidates. METHODS Novel noninvasive imaging using computed tom...
متن کاملEfficacy Analysis of a Script-based Guide for EVAR Execution: is it Possible to Reduce Patient Exposure to Contrast, Operative Time and Blood Loss even when Advanced Technologies are not Available?
INTRODUCTION Despite the patient and medical staff exposure to radiation in endovascular aneurysm repair, the benefits of this abdominal aortic aneurysm type of surgical management are justified by minor recovery time and hospitalization, as well as an option for patients not elected to conventional open repair. In this minimally invasive surgical approach, time of procedure and radiation doses...
متن کامل