Endovascular treatment of PA pseudoaneurysm caused by Swan-Ganz catheter

نویسندگان

  • Piotr N. Rudziński
  • Marcin Demkow
  • Ilona Michałowska
  • Elżbieta Abramczuk
  • Piotr Szymański
چکیده

The following case report describes a complication of Swan-Ganz catheterization and its endovascular treatment with a single coil. Application of this particular catheter in the pulmonary artery during cardiac surgery may lead to mechanical perforation and creation of an extravascular sac, which is called a pseudoaneurysm. There are different methods that lead to tamponade or closure of the leakage. Interventional cardiology procedures are nowadays the most appropriate way of treatment of Swan-Ganz catheter induced vascular complications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulmonary artery rupture as a complication of Swan-Ganz catheter application. Diagnosis and endovascular treatment: a single centre's experience

INTRODUCTION The placement of a Swan-Ganz catheter into the pulmonary artery may lead to a number of complications (2-17%). In less than 0.2% of cases Swan-Ganz catheterization results in serious vascular damage - pulmonary artery rupture (PAR). This paper presents two distinct forms of iatrogenic PAR treated endovascularly using different vascular devices. AIM To evaluate the effectiveness o...

متن کامل

Swan-Ganz catheter-induced pulmonary artery pseudoaneurysm formation: three case reports and a review of the literature.

The use of Swan-Ganz catheters has increased tremendously since they were first introduced in 1970. Their ability to give vital hemodynamic measurements in critically ill patients makes their use invaluable when providing quality medical care. The formation of pulmonary artery (PA) pseudoaneurysm from a Swan-Ganz catheter-induced perforation of the PA is a rare but potentially fatal complicatio...

متن کامل

Pulmonary alveolar hemorrhage from a pulmonary artery false aneurysm after Swan-Ganz catheterization in a thoracic aortic aneurysm patient: a case report

Pulmonary artery (PA) rupture caused by a PA Swan-Ganz catheter is a rare complication but remains fatal in almost 50% of cases. False aneurysm of the PA is a rare presentation of PA rupture and should be considered as a possible diagnosis in a patient with a new lung mass after PA catheterization. We present a case of sudden-onset pulmonary alveolar hemorrhage during cardiovascular surgery due...

متن کامل

Vertebral arteriovenous fistula: an unusual complication of Swan-Ganz catheter insertion.

The leading causes of trauma to the major craniocerebral vessels include penetrating and non penetrating trauma [1 , 2]. Because the vertebral artery is confined to the incomplete bony canal formed by the successive foramina in the transverse processes of the upper cervical vertebrae, it is less susceptible to penetrating injury than is the carotid artery [2]. A review of the literature has unc...

متن کامل

Latex anaphylaxis caused by a Swan-Ganz catheter.

A 78-year-old woman visited the division of cardiovascular disease in our hospital. She underwent a cardiac catheter examination, and a Swan-Ganz catheter was inserted. Several minutes later, she developed anaphylactic shock. She had no past history of latex allergy, but did have a banana allergy. Skin prick tests showed a positive reaction to an extract of latex gloves and an extract of the ba...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2014