Development of Liquid Refrigerant Pump for Ice-Storage Packaged Air-Conditioners

نویسندگان

  • M. Takeuchi
  • H. Kobayashi
  • K. Sato
  • M. Fujitani
  • N. Hayashi
  • H. Machida
چکیده

This paper presents the development of the low cost liquid pump. The rotary compressor developed as the gas compressor for the residential air-conditioner was converted into the liquid refrigerant pump. Problems of the liquid refrigerant pump are the reliability assessment of sliding parts and the reduction of the noise generated by discharge pulsation in this development. Therefore some modifications, i.e., from the high pressure housing to the low pressure one, and from the compression process with a discharge valve to the direct discharge compression process, were made. By solving the problems mentioned above, the development of the liquid refrigerant pump using in the ice-storage packaged air-eonditioners with the low costs and the high reliability bas been achieved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fault Detection And Diagnosis For Air Conditioners And Heat Pumps Based On Virtual Sensors

Kim, Woohyun. Ph.D., Purdue University, December 2013. Fault Detection and Diagnosis for Air Conditioners and Heat Pumps based on Virtual Sensors. Major Professor: James E. Braun, School of Mechanical Engineering. The primary goal of this research is to develop and demonstrate an integrated, on-line performance monitoring and diagnostic system with low cost sensors for air conditioning and heat...

متن کامل

Assuring Reliability of Compressors Using HFC Refrigerants

In Japan, the refrigerant used in room air-conditioners has been changed from HCFC-22 (R-22) to R-410A, a blend of HFC-32 and HFC-125 (50/50 vt%), in order to protect the ozone layer. Generally, the miscibility between the refrigerant and refrigeration oil must be assured, because the oil needs to return to the compressor from the refrigeration cycle and lubricate the sliding parts. Alternative...

متن کامل

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

Models for unitary air conditioners and heat pumps typically have difficulties in providing accurate predictions for the following situations: 1) charge modeling over a large range of charge levels, 2) two-phase refrigerant entering fixed-orifice expansion devices, 3) two-phase refrigerant entering compressors, and 4) non-uniform refrigerant mass flow allocation among evaporator circuits at low...

متن کامل

Modeling of Compressors and Expansion Devices With Two-Phase Refrigerant Inlet Conditions

Simulation models for unitary air conditioners and heat pumps usually can not provide accurate predictions in the case of two-phase refrigerant entering the compressor or fixed-area expansion device. This paper focuses on improving modeling methods in these situations. The study utilized extensive laboratory tests and detailed modeling of two unitary air conditioners, one using R-410A and the o...

متن کامل

Host-Based Architecture LON Communicat ion Gateway for Building Air-conditioner Monitoring System

Along with BACnet, LONWORKS is also increasingly accepted as a de-facto standard for building management communication protocol. A few years ago, Mitsubishi Heavy Industries developed these communication gateways for packaged air-conditioners,(1) but the recent market need is increasingly shifting to large capacity and high performance. In recent building management systems for packaged aircond...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014