Spectrophotometric Determination of Cobalt, Nickel Palladium, Copper, Ruthenium and Molybdenum Using Sodium Isoamylxanthate in Presence of Surfactants

نویسنده

  • A. K. MALIK
چکیده

A. K. MALIK Universidad Complutense de Madrid, Departamento de Quimica Analitica, Facultad de Ciencias Quimicas, Ciudad Universitaria, 28040, Madrid-SPAIN K. N. KAUL, B. S. LARK Department of Chemistry, G.N.D. University Amritsar, Punjab-INDIA W. FAUBEL Forschungszentrum Karlsruhe, Institute for Instrumental Analysis, PO 3640, 76021, Karlsruhe-GERMANY A. L. J. RAO Department of Chemistry, Punjabi University, Patiala, Punjab-INDIA

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spectrophotometric simultaneous determination of nickel, cobalt and copper by orthogonal signal correction–partial least squares

A method for the simultaneous spectrophotometric determination of nickel, cobalt and copper based on theformation of their complexes with 2-(2-Thiazolylazo)-p-Cresol (TAC) in micellar media of Triton X-100 isproposed. The absorbance spectra were recorded in the range of 500 to 800 nm. The linear concentrationrange for nickel, cobalt and copper in solution calibration sets were 0.05–1.80, 0.10–6...

متن کامل

Simultaneous Spectrophotometric Determination of Iron, Cobalt and Copper by Partial Least-Squares Calibration Method in Micellar Medium

Iron, cobalt and copper are metals, which appear together in many real samples, both natural and artificial. Recently a classical univariate micellar colorimetric method has been developed for determination of these metal ions. The organized molecular assemblies such as micelles are used in spectroscopic measurements due to their possible effects on the systems of interest. The ability of mi...

متن کامل

Simultaneous Spectrophotometric Determination of Iron, Cobalt and Copper by Partial Least-Squares Calibration Method in Micellar Medium

Iron, cobalt and copper are metals, which appear together in many real samples, both natural and artificial. Recently a classical univariate micellar colorimetric method has been developed for determination of these metal ions. The organized molecular assemblies such as micelles are used in spectroscopic measurements due to their possible effects on the systems of interest. The ability of mi...

متن کامل

Simultaneous spectrophotometric determination of lead, copper and nickel using xylenol orange by partial least squares

A partial least squares (PLS) calibration model was developed for the simultaneous spectrophotometricdetermination of Pb (ΙΙ), Cu (ΙΙ) and Ni (ΙΙ) using xylenol orange as a chromogenic reagent. The parameterscontrolling behavior of the system were investigated and optimum conditions were selected. The calibrationgraphs were linear in the ranges of 0.0–9.091, 0.0–2.719 and 0.0–2.381 ppm for lead...

متن کامل

Organometallic hydroxides of transition elements.

3. Introduction 3815 4. Group 3 Organo-hydroxides 3816 5. Group 4 Organo-hydroxides 3821 5.1. Titanium 3822 5.2. Zirconium 3823 5.3. Hafnium 3824 6. Group 5 Organo-hydroxides 3825 6.1. Vanadium 3825 6.2. Niobium 3825 6.3. Tantalum 3826 7. Group 6 Organo-hydroxides 3826 7.1. Chromium 3826 7.2. Molybdenum 3826 7.3. Tungsten 3829 8. Group 7 Organo-hydroxides 3830 8.1. Manganese 3830 8.2. Techneciu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001