Quantification of the surface stress in microcantilever biosensors: revisiting Stoney's equation.
نویسندگان
چکیده
Microcantilever biosensors in the static operation mode translate molecular recognition into a surface stress signal. Surface stress is derived from the nanomechanical cantilever bending by applying Stoney's equation, derived more than 100 years ago. This equation ignores the clamping effect on the cantilever deformation, which induces significant errors in the quantification of the biosensing response. This leads to discrepancies in the surface stress induced by biomolecular interactions in measurements with cantilevers with different sizes and geometries. So far, more accurate solutions have been precluded by the formidable complexity of the theoretical problem that involves solving the two-dimensional biharmonic equation. In this paper, we present an accurate and simple analytical expression to quantify the response of microcantilever biosensors. The equation exhibits an excellent agreement with finite element simulations and DNA immobilization experiments on gold-coated microcantilevers.
منابع مشابه
A Study on Increasing Sensitivity of Rectangular Microcantilevers Used in Biosensors
This study proposes a new microcantilever design with a rectangular hole at the fixed end of the cantilever that is more sensitive than conventional ones. A commercial finite element analysis software ANSYS is used to analyze it. The Stoney equation is first used to calculate the surface stress induced moment, and then applied to the microcantilever free end to produce deflection. The stress an...
متن کاملCalculation of Stress And Deflection In Double Layer Microcantilever For Biosensor Application
In microcantilever-based biosensor, a sensitive layer plays an important role as a place for the establishment of functional layer for detecting molecules target. When a sensitive layer is coated on the microcantilever surface, a surface stress change is induced as a consequence of adsorbate-surface interaction, resulting in a deflection of the microcantilever. However, the microcantilever with...
متن کاملMicrocantilever biosensors based on conformational change of proteins.
Microcantilevers (MCLs) hold a position as a cost-effective and highly sensitive sensor platform for medical diagnostics, environmental analysis and fast throughput analysis. MCLs are unique in that adsorption of analytes on the microcantilever (MCL) surface changes the surface characteristics of the MCL and results in bending of the MCL. Surface stress due to conformation change of proteins an...
متن کاملHigh S/N Ratio Slotted Step Piezoresistive Microcantilever Designs for Biosensors
This study proposes new microcantilever designs in slotted step configuration to improve the S/N ratio of surface stress-based sensors used in physical, chemical, biochemical and biosensor applications. The cantilevers are made of silicon dioxide with a u-shaped silicon piezoresistor in p-doped. The cantilever step length and piezoresistor length is varied along with the operating voltage to ch...
متن کاملDeflection, Frequency, and Stress Characteristics of Rectangular, Triangular, and Step Profile Microcantilevers for Biosensors
This study presents the deflection, resonant frequency and stress results of rectangular, triangular, and step profile microcantilevers subject to surface stress. These cantilevers can be used as the sensing element in microcantilever biosensors. To increase the overall sensitivity of microcantilever biosensors, both the deflection and the resonant frequency of the cantilever should be increase...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nanotechnology
دوره 23 47 شماره
صفحات -
تاریخ انتشار 2012