Comparison of the measured pre-ejection periods and left ventricular ejection times between echocardiography and impedance cardiography for optimizing cardiac resynchronization therapy
نویسندگان
چکیده
BACKGROUND The pre-ejection period (PEP) and left ventricular ejection time (LVET) are easily measured by impedance cardiography (ICG). We hypothesized that the PEP/LVET measured by ICG would correlate with that measured by echocardiography, and that PEP/LVET measured by ICG would be useful for cardiac resynchronization therapy (CRT) optimization. METHODS Newly CRT implanted patients were optimized by echocardiography. The PEP/LVET was measured by echocardiography and ICG in two different settings: optimized setting and right ventricle (RV)-only pacing. RESULTS The PEP/LVET was significantly decreased in the optimized setting compared with that in RV-only pacing (0.62±0.13 vs 0.75±0.16, p<0.05). The PEP/LVET values calculated by ICG and echocardiography were positively correlated (r=0.553, p=0.003). CONCLUSION ICG was useful for the optimization of CRT.
منابع مشابه
Comparison of Cardiac Function in Young Patients with Thalassemia Intermedia and Healthy Individuals Using Echocardiography Method
Background: Cardiac dysfunction due to chronic anemia and hemosiderosis are the major causes of death among patients with thalassemia intermedia. This study was performed to compare the cardiac function in thalassemia intermedia patients with normal subjects by means of echocardiography. Materials and Methods: This was a case-control study performed on 22 patients affected by thalassemia int...
متن کاملقلب نگاری امپدانسی روشی برای پایش غیرتهاجمی حجم ضربه ای: یک مطالعه ی مقدماتی
Abstract Background: Impedance cardiography (ICG) is a simple and inexpensive technique for non-invasive and continues measurement of stroke volume. Due to non-invasive nature, ICG is becoming increasingly used in research and clinical applications. With regard to lack of domestic impedance cardiograph and limited similar imported products in the country, an inexpensive and portable protot...
متن کاملImpedance cardiography: a useful and reliable tool in optimization of cardiac resynchronization devices.
AIMS Optimizing cardiac resynchronization therapy (CRT) devices has become more complex since modification of both atrioventricular (AV) and interventricular (VV) stimulation intervals has become possible. The current paper presents data from the routine use of impedance cardiography (IC)-based cardiac output (CO) measurements to guide the optimization of AV- and VV-interval timing of CRT devic...
متن کاملNormal left ventricular systolic time intervals assessed by pulsed wave Doppler echocardiography in the Turkmen horse of Iran
The Turkmen horse is one of the oldest and purest breeds in the world. There is no information with regards to the normal echocardiographic parameters of this horse regarding to cardiac diseases. Pulsed-wave (PW) Doppler echocardiography was performed on 42 clinically normal 3- to 15-year-old racing Turkmen horses. There were 26 stallions and 16 mares. The left ventricular isovolumetric contrac...
متن کاملEvaluation of Cardiac Function in Patients with Thalassemia Intermedia
Abstract Background Thalassemia intermedia is a variety of beta thalassemia which shows clinical symptoms somewhere between asymptomatic carriers and thalassemia major. Cardiac dysfunctions due to chronic anemia and hemosiderosis are the major causes of death in these patients. The purpose of this study is to evaluate cardiac function in these patients by echocardiography. Materials and Met...
متن کامل