Intraoperative evaluation of coronary artery bypass graft anastomoses with high-frequency epicardial echocardiography: experimental validation and initial patient studies.

نویسندگان

  • L F Hiratzka
  • D D McPherson
  • W C Lamberth
  • B Brandt
  • M L Armstrong
  • E Schröder
  • M Hunt
  • R Kieso
  • M D Megan
  • P K Tompkins
چکیده

There is currently no accepted approach for intraoperative evaluation of the technical adequacy of coronary artery bypass graft anastomoses. High-frequency epicardial echocardiography performed intraoperatively could assess coronary artery bypass graft anastomoses by providing on-line short-axis (cross-sectional) and longitudinal two-dimensional images of the vessels. To validate measurements of anastomoses with high-frequency epicardial echocardiography, luminal diameter determined by high-frequency epicardial echocardiography was compared with that determined histologically after perfusion fixation in 12 dogs studied after coronary artery bypass grafting. Technical errors were deliberately created in some grafts. The results of these animal validation studies showed that maximum luminal diameter of the anastomosis by high-frequency epicardial echocardiography correlated well with histologic measurements (r = .92; high-frequency epicardial echocardiography = 0.8 histology + 0.3). All deliberately created technical errors were detected by an independent observer using high-frequency epicardial echocardiography. After completion of the animal studies, we demonstrated the clinical applicability of this approach in 12 patients. Fifteen coronary artery bypass graft anastomoses were examined intraoperatively with high-frequency epicardial echocardiography. The measured maximum luminal diameter of the anastomosis was greater than the maximum luminal diameter of the native artery, as expected, in all end-to-side anastomoses. However, the maximum luminal diameter of the side-to-side anastomoses was equal to or slightly less than that of the native artery. In this initial patient group, minor technical errors were noted in two of 15 graft anastomoses. In conclusion, high-frequency epicardial echocardiography can accurately measure coronary arterial bypass graft anastomoses and has potential for intraoperative detection of technical errors and inadequacies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Factors Influencing Liver Function Test in On-Pump Coronary Artery Bypass Graft Surgery

Background: Liver dysfunction during on-pump coronary artery bypass graft surgery (CABG) is a rare complication but is associated with significant morbidity and mortality. The ability to identify high-risk patients may be helpful in planning appropriate management strategies. We aimed to evaluate the factors influencing liver function tests during on-pump CABG.Methods: In 146 patients scheduled...

متن کامل

Intraoperative color Doppler ultrasound assessment of LIMA-to-LAD anastomoses in off-pump coronary artery bypass grafting.

BACKGROUND Although techniques for off-pump coronary artery bypass grafting (CABG) are continually being refined, angiographic follow-up studies have indicated a higher rate of anastomoses-related stenoses than expected after traditional on-pump CABG. This study was performed to evaluate the use of intraoperative epicardial color Doppler ultrasound to quality-assess left internal mammary artery...

متن کامل

Comparison of the Graft Angles Effects on the Temporal Wall Shear Stress Gradients in the Aorto-Coronary and Coronary-Coronary Bypasses

In this theoretical study, the effect of various types of bypass graft angles on the flow field, has been investigated specially on the temporal Wall Shear Stress (WSS) on the toe, heel and some locations on the bed of the Left Anterior Descending (LAD) artery at the anastomoses areas in the Aorto-Coronary (AC) and Coronary-Coronary (CC) bypasses. Flow fields in both bypasses with angles of...

متن کامل

Detection of internal thoracic artery dissection at coronary anastomosis using intraoperative 15-MHz high-frequency epicardial ultrasound.

A 66-year-old man with a history of diabetes mellitus presented with angina pectoris with 3-vessel disease, and he underwent off-pump coronary artery bypass grafting via median sternotomy. After performing bypass grafting of the left internal thoracic artery to the left anterior descending artery, the appearance of anastomosis configuration appeared to be acceptable. However, transit time flow ...

متن کامل

بررسی نقش متادون به‌عنوان یک مخدر مناسب در عمل جراحی و پیوند عروق کرونر در معتادان به تریاک

Todays coronary artery bypass graft (CABG) is the most frequent among open heart surgeries. In our country some of people that are candidate for coronary artery bypass graft, are addict and they use opium daily, that cause multiple complication during intraoperative and postoperative periods. Inspite of several studies that methadone is used to anti-addiction therapy and for reducing th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 73 6  شماره 

صفحات  -

تاریخ انتشار 1986