Quantitating physical activity in COPD using a triaxial accelerometer.

نویسندگان

  • B G Steele
  • L Holt
  • B Belza
  • S Ferris
  • S Lakshminaryan
  • D M Buchner
چکیده

STUDY OBJECTIVE To determine the reliability, validity, and stability of a triaxial accelerometer for walking and daily activity measurement in a COPD sample. DESIGN Cross-sectional, correlational, descriptive design. SETTING Outpatient pulmonary rehabilitation program in a university-affiliated Veterans Affairs medical center. PARTICIPANTS Forty-seven outpatients (44 men and 3 women) with stable COPD (FEV(1), 37% predicted; SD, 16%) prior to entry into a pulmonary rehabilitation program. MEASUREMENTS AND RESULTS Test-retest reliability of a triaxial movement sensor (Tritrac R3D Research Ergometer; Professional Products; Madison, WI) was evaluated in 35 of the 47 subjects during three standardized 6-min walks (intraclass correlation coefficient [rICC] = 0.84). Pearson correlations evaluated accelerometer concurrent validity as a measure of walking (in vector magnitude units), compared to walking distance in all 47 subjects during three sequential 6-min walks (0. 84, 0.85, and 0.95, respectively; p < 0.001). The validity of the accelerometer as a measure of daily activity over 3 full days at home was evaluated in all subjects using Pearson correlations with other indicators of functional capacity. The accelerometer correlated with exercise capacity (maximal 6-min walk, r = 0.74; p < 0.001); level of obstructive disease (FEV(1) percent predicted, r = 0.62; p < 0.001); dyspnea (Functional Status and Dyspnea Questionnaire, dyspnea over the past 30 days, r = - 0.29; p < 0.05); and activity self-efficacy (Activity Self-Efficacy Questionnaire, r = 0.43; p < 0.01); but not with self-report of daily activity (Modified Activity Recall Questionnaire, r = 0.14; not significant). Stability of the accelerometer to measure 3 full days of activity at home was determined by an rICC of 0.69. CONCLUSIONS This study provides preliminary data suggesting that a triaxial movement sensor is a reliable, valid, and stable measure of walking and daily physical activity in COPD patients. It has the potential to provide more precise measurement of everyday physical functioning in this population than self-report measures currently in use, and measures an important dimension of functional status not previously well-described.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of the triaxial accelerometer for the evaluation of physical activity in Japanese patients with COPD.

OBJECTIVE The quantification of physical activity is useful for the management of chronic obstructive pulmonary disease (COPD) but has not been fully established yet. The DynaPort Activity Monitor(®) (DAM), a triaxial accelerometer is the only well validated accelerometer in Caucasians but it has not been validated in Japanese COPD patients. We initially evaluated the reproducibility of the DAM...

متن کامل

The validity of the non-exercise activity thermogenesis questionnaire evaluated by objectively measured daily physical activity by the triaxial accelerometer

BACKGROUND Physical inactivity is a major cardiovascular risk factor. Recently, we showed that non-exercise activity thermogenesis (NEAT) assessed by the self-reported questionnaire is favorably associated with metabolic risks in patients with type 2 diabetes. The purpose of the present study was to examine the validity of the questionnaire by comparing with objectively measured daily physical ...

متن کامل

Comparison of Self-Reported and Accelerometer-Assessed Physical Activity in Older Women

BACKGROUND Self-reported physical activity measures continue to be validated against accelerometers; however, the absence of standardized, accelerometer moderate-to-vigorous physical activity (MVPA) definitions has made comparisons across studies difficult. Furthermore, recent accelerometer models assess accelerations in three axes, instead of only the vertical axis, but validation studies have...

متن کامل

Real-time estimation of daily physical activity intensity by a triaxial accelerometer and a gravity-removal classification algorithm.

We have recently developed a simple algorithm for the classification of household and locomotive activities using the ratio of unfiltered to filtered synthetic acceleration (gravity-removal physical activity classification algorithm, GRPACA) measured by a triaxial accelerometer. The purpose of the present study was to develop a new model for the immediate estimation of daily physical activity i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 117 5  شماره 

صفحات  -

تاریخ انتشار 2000