Reproducibility of the signal averaged P wave: time and frequency domain analysis.
نویسندگان
چکیده
OBJECTIVE To assess the reproducibility of time and frequency domain variables derived from the signal averaged P wave. DESIGN Longitudinal within patient study. SETTING Regional cardiothoracic centre. PATIENTS 20 patients (10 with documented paroxysmal atrial fibrillation and 10 normal controls) were studied on three occasions to assess the reproducibility of repeated signal averaged P wave recordings. Digital P wave recordings were made on a further 10 patients on a single occasion and the recordings signal averaged twice in order to assess the reproducibility of the averaging system itself in the absence of biological variation. MAIN OUTCOME MEASURES P wave duration, spatial velocity, and energies contained in frequency bands from 20, 30, and 60-150 Hz of the P wave spectrum were measured after P wave specific signal averaging. Coefficients of reproducibility were calculated for paired signal averaged P waves derived by signal averaging the same digital recordings on two separate occasions, for recordings performed in the same patients immediately after each other ("back to back") and those performed one week apart. RESULTS System reproducibility when the same digital P wave recordings were signal averaged on two separate occasions was high (< 11% for all variables). For P wave duration the coefficient of reproducibility was 11.4% for back to back recordings and 13.1% for those one week apart. The reproducibility of spatial velocity and P wave energy was low. Variation in P wave morphology was noted when successive P waves from the same subject were examined. If recordings with the same P wave morphology were analysed the reproducibility of spatial velocity and P wave energy improved but remained significantly poorer than that for P wave duration. CONCLUSIONS P wave duration is reproducible within subjects in the short and medium term. Frequency domain and spatial velocity analysis are poorly reproducible, due more to spontaneous variation in P wave morphology than to instability of the signal averaging process. This may limit the utility of signal averaged P wave variables other than duration for the prediction of atrial arrhythmia.
منابع مشابه
Application of Single-Frequency Time-Space Filtering Technique for Seismic Ground Roll and Random Noise Attenuation
Time-frequency filtering is an acceptable technique for attenuating noise in 2-D (time-space) and 3-D (time-space-space) reflection seismic data. The common approach for this purpose is transforming each seismic signal from 1-D time domain to a 2-D time-frequency domain and then denoising the signal by a designed filter and finally transforming back the filtered signal to original time domain. ...
متن کاملComplex feature analysis of center of pressure signal for age-related subject classification
Purpose: The aim of this study was to characterize prolonged standing and its effect on postural control in elderly individuals in comparison to adults.Materials and Methods: The elderly individuals’ behavior during standing and how demanding such a task is for them, is still unknown. We recorded the center of pressure (COP) position of 12 elder and 15 young participants while they were standin...
متن کاملA Time-Domain Method for Shape Reconstruction of a Target with Known Electrical Properties (RESEARCH NOTE)
This paper uses a method for shape reconstruction of a 2-D homogeneous object with arbitrary geometry and known electrical properties. In this method, the object is illuminated by a Gaussian pulse, modulated with sinusoidal carrier plane wave and the time domains’ footprint signal due to object presence is used for the shape reconstruction. A nonlinear feedback loop is used to minimize the diff...
متن کاملThe Transient Behavior of LC and Ring Oscillators under External Frequency Injection
In this work, time domain analysis is used to solve Adler’s equation in order to obtain the required time, for an oscillator under external injection, reaching the steady-state condition. Mathematical approach has been applied to fully describe the transient of frequency acquisition in injection-locked LC and Ring oscillators considering their time-varying nature. Then, the analysis is verifie...
متن کاملUn ltered signal-averaged P wave analysis { further validation of the method
Background: The study was designed to explore the impact of di erent methodologies on P wave duration estimates. Furthermore, the required recording length to ensure reproducibility from un ltered signal-averaged P wave analysis was investigated. Finally, the reproducibility of P wave morphology classi cation was investigated and an algorithm for automated classi cation was designed. Methods: 1...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Heart
دوره 77 5 شماره
صفحات -
تاریخ انتشار 1997