Percutaneous repair of aortic aneurysms: a prospective study of suture-mediated closure devices.

نویسندگان

  • J Watelet
  • J-C Gallot
  • P Thomas
  • F Douvrin
  • D Plissonnier
چکیده

PURPOSE To evaluate prospectively the safety and efficacy of totally percutaneous placement of abdominal and thoracic aortic endografts using the Prostar XL suture-mediated closure system. METHODS From January 2002 to January 2005, we attempted to insert percutaneously all bifurcated abdominal aortic and thoracic endografts. Consecutive patients (25 men, four women), with mean age 74.9 years (range 44-84), underwent endovascular repair for 20 abdominal aortic aneurysms (AAA) and nine thoracic aortic aneurysms (repeat operation in one case). Endografts used included 21 Zenith (Cook), eight Talent (Medtronic), one AneuRx (Medtronic). For the <> technique, two Prostar XL 8F were used to close 22-24F access sites and one Prostar XL 10F to close 16F access sites. RESULTS Procedural success was achieved in 21/29 (72.4%) patients and in 39/47 access sites (83%). Closure of 22-24F access sites with tandem 8F Prostar devices was successful in 23/29 (79.3%) cases. Closure of 16F access sites with 10F Prostar device was successful in 16/18 (88.8%) cases. There were seven peri-procedural failures requiring surgery to repair the femoral artery in three cases. Four access complications healed without intervention. Overall 25/29 (86.2%) patients had complete percutaneous repair. No late complications were detected during follow-up (median 17.5 months). CONCLUSIONS Percutaneous treatment of patients with AAA and thoracic aneurysms is feasible in most cases, with a very low risk of access-related complication, providing that the operator has sufficient practical experience of this technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Percutaneous closure devices for endovascular repair of infrarenal abdominal aortic aneurysms: a prospective, non-randomized comparative study.

PURPOSE This study was designed to describe and evaluate our preliminary results with a percutaneous arterial closure device as compared to those obtained with conventional femoral surgical cut down during endovascular repair of abdominal aortic aneurysms (AAA). MATERIAL AND METHODS Between January 2004 and December 2006, 40 of 86 AAA patients selected for endovascular repair met the criteria...

متن کامل

Percutaneous endovascular repair of infrarenal abdominal aortic aneurysms: a feasibility study.

BACKGROUND Endovascular grafting has markedly reduced the invasiveness of the treatment of abdominal aortic aneurysms. By using a modification of technique for available closure devices, we have been able to achieve percutaneous repair of aneurysms. This study reviewed our initial experience with this technique. METHODS Demographics and background data from patients undergoing endovascular re...

متن کامل

Total percutaneous endovascular aneurysm repair with the dual 6-F Perclose-AT preclosing technique: a case-control study.

PURPOSE To determine the safety and efficacy of total percutaneous access closure for endovascular aortic aneurysm repair with a suture-mediated preclosing technique. MATERIALS AND METHODS One hundred thirty-two femoral access sites in 70 patients who underwent endovascular aortic aneurysm repair were closed percutaneously with off-label use of two F-6 Perclose AT devices preapplied at a 90 d...

متن کامل

The use of percutaneous suture-mediated closure for the management of 14 French femoral venous access.

BACKGROUND Little has been reported regarding the utility or outcomes of femoral venous vascular closure using arterial suture closure devices. We describe results using a pre-closure approach with a 6 French (Fr) Perclose Closer S device in patients who underwent antegrade aortic valvuloplasty using 14 Fr percutaneous femoral venous access catheters. METHODS Forty-five patients underwent ant...

متن کامل

New surgical modification of fascial closure following endovascular aortic pathology repair

INTRODUCTION There are clear benefits of percutaneous versus open femoral access for endovascular aortic pathology repair. All closing devices commercially available are expensive. Surgical closure of the femoral artery risks potential prolonged wound healing and as a consequence longer hospital stay. Fascial closure is a technique that remains an interesting option. AIM To evaluate the effic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery

دوره 32 3  شماره 

صفحات  -