Two Proximal Skin Electrodes—A Body Sensor for Respiration Rate
نویسنده
چکیده
We propose a new body sensor for extracting the respiration rate based on the amplitude changes in the body surface potential differences between two proximal body electrodes. The sensor could be designed as a plaster-like reusable unit that can be easily fixed onto the surface of the body. It could be equipped either with a sufficiently large memory for storing the measured data or with a low-power radio system that can transmit the measured data to a gateway for further processing. We explore the influence of the sensor’s position on the quality of the extracted results using multi-channel ECG measurements and considering all the pairs of two neighboring electrodes as potential respiration-rate sensors. The analysis of the clinical measurements, which also include reference thermistor-based respiration signals, shows that the proposed approach is a viable option for monitoring the respiration frequency and for a rough classification of breathing types. The obtained results were evaluated on a wireless prototype of a respiration body sensor. We indicate the best positions for the respiration body sensor and prove that a single sensor for body surface potential difference on proximal skin electrodes can be used for combined measurements of respiratory and cardiac activities.
منابع مشابه
Two Proximal Skin Electrodes — A Respiration Rate Body Sensor
We propose a new body sensor for extracting the respiration rate based on the amplitude changes in the body surface potential differences between two proximal body electrodes. The sensor could be designed as a plaster-like reusable unit that can be easily fixed onto the surface of the body. It could be equipped either with a sufficiently large memory for storing the measured data or with a low-...
متن کاملWearable Contactless Respiration Sensor Based on Multi-Material Fibers Integrated into Textile
In this paper, we report on a novel sensor for the contactless monitoring of the respiration rate, made from multi-material fibers arranged in the form of spiral antenna (2.45 GHz central frequency). High flexibility of the used composite metal-glass-polymer fibers permits their integration into a cotton t-shirt without compromising comfort or restricting movement of the user. At the same time,...
متن کاملWireless Bio- medical Sensor Network for Heartbeat and Respiration Detection
A wireless bio-medicalr sensor Network was designed to detect a human heartbeat and respiration signals without direct skin contact. In order to design a wireless bio-medical sensor quantitatively, the signal to-noise ratio (SNR) in the baseband output of a sensor should be calculated. Therefore, we analyzed the SNR of the wireless biomedical sensor, considering the signal power attenuation in ...
متن کاملPotassium-Selective Membrane Sensor Based on Two Recently Synthesized Poly(oxyethylene) Derivatives
Two poly(oxyethylene) derivatives 1.10-bis(2'-benzoic acid)-1,4,7,1-tetradecane (L1) and 1,7-bis(2'-benzoic acid)-1,4,7-trioxaheptane (L2) were used as suitable ionophores for the preparation of potassium-selective PVC-membrane electrodes. The resulting electrodes based on L1 and L2 exhibit linear responses to the activity of K+ ions within the concentration ranges of 3.1<em...
متن کاملInvestigation of combined effects of noise and low air temperature on human-environmental comfort and physiological responses- An experimental study
Background and Aim: Combined exposure to noise and temperature can affect the neurophysiological responses of the office staff. The present study was done to investigate the impacts of combined exposure to noise and low air temperature on physiological responses and environmental comfort. Methods: In this experimental study, the studied population included the students who were randomly selecte...
متن کامل