Laryngeal tube suction for airway management during in-hospital emergencies
نویسندگان
چکیده
OBJECTIVE: The role of supraglottic airway devices in emergency airway management is highlighted in international airway management guidelines. We evaluated the application of the new generation laryngeal tube suction (LTS-II/LTS-D) in the management of in-hospital unexpected difficult airway and cardiopulmonary resuscitation. METHODS: During a seven-year period, patients treated with a laryngeal tube who received routine anesthesia and had an unexpected difficult airway (Cormack Lehane Grade 3-4), who underwent cardiopulmonary resuscitation, or who underwent cardiopulmonary resuscitation outside the operating room and had a difficult airway were evaluated. Successful placement of the LTS II/LTS-D, sufficient ventilation, time to placement, number of placement attempts, stomach content, peripheral oxygen saturation/end-tidal carbon dioxide development (SpO2/etCO2) over 5 minutes, subjective overall assessment and complications were recorded. RESULTS: In total, 106 adult patients were treated using an LTS-II/LTS-D. The main indication for placement was a difficult airway (75%, n=80), followed by cardiopulmonary resuscitation (25%, n=26) or an overlap between both (18%, n=19). In 94% of patients (n=100), users placed the laryngeal tube during the first attempt. In 93% of patients (n=98), the tube was placed within 30 seconds. A significant increase in SpO2 from 97% (0-100) to 99% (5-100) was observed in the whole population and in cardiopulmonary resuscitation patients. The average initial etCO2 of 39.5 mmHg (0-100 mmHg) decreased significantly to an average of 38.4 mmHg (10-62 mmHg) after 5 minutes. A comparison of cardiopulmonary resuscitation patients with non-cardiopulmonary resuscitation patients regarding gastric contents showed no significant difference. CONCLUSIONS: LTS-D/LTS-II use for in-hospital unexpected difficult airway management provides a secure method for primary airway management until other options such as video laryngoscopy or fiber optic intubation become available.
منابع مشابه
DISPOSABLE VERSUS REUSABLE LARYNGEAL TUBE SUCTION FOR VENTILATION IN PATIENTS UNDERGOING LAPAROSCOPIC CHOLECYSTECTOMY Disposable Versus Reusable Laryngeal Tube Suction for Ventilation in Patients Undergoing Laparoscopic Cholecystectomy
The laryngeal tube suction II (LTS-II; VBM, Medizintechnik GmbH, Sulz, Germany) is a recent version of the laryngeal tube (LT) family of supraglottic airway devices originally intended for emergency airway management including out of hospital use 1,2 and unexpected difficult airway situations 3,4, but which are currently also used during general anaesthesia 5-11. The original LT consists of an ...
متن کاملSafe Use of Flammable Endotracheal Tubes During Anesthesia for Laryngeal Laser Surgery-Report of 1024 Cases and a Brief Literature Review
Introduction: One of the major concerns in laryngeal laser surgery is the risk of airway fire. The introduction ofwrapped tubes and metal tubes has reduced the fire hazards. However, these tubes are expensive and do not provide convenient access to the surgical field. There are few laboratory studies addressing the resistance of polyvinylchloride tubes against ignition in the given circum...
متن کاملCase Report of an open Neck Procedure Complication Associated with Laryngeal Mask Airway Use
Introduction: The laryngeal mask airway (LMA) is a safe method to establish airway control during general anaesthesia. In otolaryngology surgery, the use of a LMA is well established in ear surgery; however, the use of a LMA during open neck procedures remains controversial. We report a case in which the pharyngeal distortion by the LMA cuff resulted in an iatrogenic complication. Case Report...
متن کاملمقایسه مقاومت و کمپلیانس دینامیک راه هوایی بین لوله تراشه کافدار و لوله لارنژیال در بیهوشی داخل وریدی کامل(TIVA) Comparing Air Way Resistance and Dynamic Compliance of Tracheal Tube and Laryngeal Tube in TIVA
Background & Aim: The aim of this study was to compare air way resistance and dynamic compliance of tracheal tube and laryngeal tube in TIVA(Total Intravenous Anesthesia). Nowadays, low airway resistance and dynamic compliance improvement during the mechanical ventilation whether in ICU or during general anesthesia, especially in patients with pulmonary diseases, is a favorable purpose to c...
متن کاملSupraglottic airway devices.
Supraglottic airway devices are developed with increasing frequency following the overwhelming success of the laryngeal mask airway (LMA). Currently, the LMA, the ProSeal laryngeal mask airway (PLMA), the laryngeal tube (LT), the laryngeal tube with integrated suctioning tube (LTS) and the oesophageal tracheal combitube (OTC) are the best evaluated and most widespread devices. Both the LMA and ...
متن کامل