Phase-sensitive optical low-coherence reflectometry for the detection of analyte concentrations.
نویسندگان
چکیده
Optical techniques may potentially be used for noninvasive glucose sensing. We investigated the application of phase-sensitive optical low-coherence reflectometry (PS-OLCR) to the measurement of analyte concentrations. The dependence of the PS-OLCR signal on the concentration of various analytes, including aqueous solutions of glucose, calcium chloride, magnesium chloride, sodium chloride, potassium chloride, potassium bicarbonate, urea, bovine serum albumin, and bovine globulin, were determined in clear and turbid media. Obtained results demonstrated (1) a high degree of sensitivity and accuracy of the phase measurements of analyte concentrations with PS-OLCR; (2) a concentration-dependent change in the phase-shift for glucose that is significantly greater than that of other analytes sampled over the same physiological range; and (3) a high submillimolar sensitivity of PS-OLCR for the measurement of glucose concentration. Further exploration of the application of PS-OLCR to the noninvasive, sensitive, and specific monitoring of glucose concentration seems warranted.
منابع مشابه
Adaptive optical coherence-domain reflectometry using photorefractive quantum wells
Adaptive optical-coherence-domain reflectometry (OCDR) is performed by use of an adaptive interferometer and homodyne detection. The adaptive element of the interferometer is a photorefractive quantum-well device in a two-wave mixing geometry. The mixing self-adaptively maintains constant relative phase between the signal and reference waves and dynamically compensates gross movements of the sa...
متن کاملDistributed measurements of fiber birefringence and diametric load using optical low-coherence reflectometry and fiber gratings.
Polarization sensitive optical low-coherence reflectometry (OLCR) is used for measuring the complex fiber Bragg gratings (FBG) reflection coefficient. We determine the beat length directly from oscillations in the OLCR amplitude with a resolution of 10(-6) and a spatial resolution only limited by the minimum beat length or the coherence length of the light source. Using the OLCR amplitude and p...
متن کاملSpectral-domain optical coherence reflectometric sensor for highly sensitive molecular detection.
We describe what we believe to be a novel use of spectral-domain optical coherence reflectometry (SD-OCR) for highly sensitive molecular detection in real time. The SD-OCR sensor allows identification of a sensor surface of interest in an OCR depth scan and monitoring the phase alteration due to molecular interaction at that surface with subnanometer optical thickness sensitivity. We present su...
متن کاملPhase-slope and group-dispersion calculations in the frequency domain by simple optical low-coherence reflectometry.
We report a new method by which phase slope and group dispersion can be calculated with a simple optical low-coherence reflectometer to quantify physiological conditions. A discrete-time signal processing algorithm based on the first and second derivatives of the phase with respect to wave number was developed from discrete-time Fourier properties. The algorithm avoids the 2pi ambiguity associa...
متن کاملPhase Noise Considerations in Coherent Optical FMCW Reflectometry
phase noise, coherent reflectometry, FMCW, Rayleigh backscattering, fiberoptic interferometry An analysis of coherent optical FMCW is presented. It shows the limitations imposed on measurements of discrete reflections and of Rayleigh backscattering due to phase noise originating in the finite coherence length of the optical source. The dependence of the range for accurate measurements on partic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied optics
دوره 43 17 شماره
صفحات -
تاریخ انتشار 2004