Megavoltage cone-beam CT: system description and clinical applications.

نویسندگان

  • Olivier Morin
  • Amy Gillis
  • Josephine Chen
  • Michèle Aubin
  • M Kara Bucci
  • Mack Roach
  • Jean Pouliot
چکیده

In this article, we describe a clinical mega-voltage cone-beam computed tomography (MV CBCT) system, present the image acquisition and patient setup procedure, discuss the positioning accuracy and image quality, and illustrate its potential use for image-guided radiation therapy (IGRT) through selected clinical examples. The MV CBCT system consists of a standard linear accelerator equipped with an amorphous-silicon flat panel electronic portal-imaging device adapted for mega-electron volt (MeV) photons. An integrated computer workspace provides automated acquisition of projection images, image reconstruction, CT to CBCT image registration, and couch shift calculation. The system demonstrates submillimeter localization precision and sufficient soft-tissue resolution to visualize structures such as the prostate. In our clinic, we have used the MV CBCT system to detect nonrigid spinal cord distortions, monitor tumor growth and shrinkage, and locate and position stationary tumors in the lung. MV CBCT has also greatly improved the delineation of structures in CT images that suffer from metal artifacts. MV CBCT has undergone significant development in the last few years. Current image quality has already proven sufficient for many IGRT applications. Moreover, we expect the range of clinical applications for MV CBCT to grow as imaging technology continues to improve.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Literature Review Image-guided radiation therapy using computed tomography in radiotherapy

The sharp dose gradients in intensity-modulated radiation therapy increase the treatment sensitivity to various interand intra-fractional uncertainties, in which a slight anatomical change may greatly alter the actual dose delivered. Image-guided radiotherapy refers to the use of advanced imaging techniques to precisely track and correct these patient-specific variations in routine treatment. I...

متن کامل

Low‐dose 2.5 MV cone‐beam computed tomography with thick CsI flat‐panel imager

Most of the treatment units, both new and old models, are equipped with a megavoltage portal imager but its use for volumetric imaging is limited. This is mainly due to the poor image quality produced by the high-energy treatment beam (> 6MV). A linac at our center is equipped with a prototype 2.5 MV imaging beam. This study evaluates the feasibility of low-dose megavoltage cone-beam imaging wi...

متن کامل

Cone Beam CT Evaluation of the Bony Changes in the Temporomandibular Joint and the Association with the Clinical Symptoms of Temporomandibular Joint Disorders

Introduction: Temporomandibular joint (TMJ) disorders are among the most prevalent abnormalities of the jaw, which affect the masticatory system, including the muscles, TMJ, and tendons. Clinical examination alone cannot determine the cause of temporomandibular disorder (TMD). In most cases, the cause of TMD and a proper treatment plan are determined based on imaging modalities. The present stu...

متن کامل

Cone-Beam Computed Tomography (CT) for a Megavoltage Linear Accelerator (LINAC) Using an Electronic Portal Imaging Device (EPID) and the Algebraic Reconstruction Technique (ART)

This study investigates the feasibility and applicability of cone beam CT for a megavoltage therapeutic LINAC. A Rando head phantom was irradiated using the 15 MV beam of a Varian 2100C LINAC at MSKCC for gantry angles from -102° to 102° with a 2° increment. The projection image for each gantry angle was obtained using a Varian Mark II EPID. Reference images without phantom were also collected ...

متن کامل

Metal artifact reduction through MVCBCT and kVCT in radiotherapy

This study proposes a new method for removal of metal artifacts from megavoltage cone beam computed tomography (MVCBCT) and kilovoltage CT (kVCT) images. Both images were combined to obtain prior image, which was forward projected to obtain surrogate data and replace metal trace in the uncorrected kVCT image. The corrected image was then reconstructed through filtered back projection. A similar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical dosimetry : official journal of the American Association of Medical Dosimetrists

دوره 31 1  شماره 

صفحات  -

تاریخ انتشار 2006