High-resolution 3D isotropic MR imaging of mouse flank tumours obtained in vivo with solenoid RF micro-coil.

نویسندگان

  • W M Holmes
  • S Maclellan
  • B Condon
  • C Dufès
  • T R J Evans
  • I F Uchegbu
  • A G Schätzlein
چکیده

The investigation of mouse flank tumours by magnetic resonance imaging (MRI) is limited by the achievable spatial resolution, which is generally limited by the critical problem of signal-to-noise ratio. Sensitivity was improved by using an optimized solenoid RF micro-coil, built into the animal cradle. This simple design did not require extensive RF engineering expertise to construct, yet allowed high-resolution 3D isotropic imaging at 60 x 60 x 60 microm(3) for a flank tumour in vivo, revealing the heterogeneous internal structure of the tumour. It also allowed dynamic contrast enhanced (DCE) experiments and angiography (MRA) to be performed at 100 x 100 x 100 microm(3) resolution. The DCE experiments provided an excellent example of the diffusive spreading of contrast agent into less vascularized tumour tissue. This work is the first step in using high-resolution 3D isotropic MR to study transport in mouse flank tumours.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A combined solenoid-surface RF coil for high-resolution whole-brain rat imaging on a 3.0 Tesla clinical MR scanner.

Rat brain models effectively simulate a multitude of human neurological disorders. Improvements in coil design have facilitated the wider utilization of rat brain models by enabling the utilization of clinical MR scanners for image acquisition. In this study, a novel coil design, subsequently referred to as the rat brain coil, is described that exploits and combines the strengths of both soleno...

متن کامل

In vivo multiple-mouse MRI at 7 Tesla.

We developed a live high-field multiple-mouse magnetic resonance imaging method to increase the throughput of imaging studies involving large numbers of mice. Phantom experiments were performed in 7 shielded radiofrequency (RF) coils for concurrent imaging on a 7 Tesla MRI scanner outfitted with multiple transmit and receive channels to confirm uniform signal-to-noise ratio and minimal ghost ar...

متن کامل

In vivo absolute quantification for mouse muscle metabolites using an inductively coupled synthetic signal injection method and newly developed (1) H/(31) P dual tuned probe.

PURPOSE To obtain robust estimates of (31) P metabolite content in mouse skeletal muscles using our recently developed MR absolute quantification method and a custom-built (1) H/(31) P dual tuned radiofrequency (RF) coil optimized for mouse leg. MATERIALS AND METHODS We designed and fabricated a probe consisting of two dual tuned (1) H/(31) P solenoid coils: one leg was inserted to each solen...

متن کامل

An eight-channel phased array RF coil for spine MR imaging at 7 T.

OBJECTIVE To develop a transmit/receive radiofrequency (RF) array for MR imaging of the human spine at 7 T. The prototype is characterized in simulations and bench measurements, and the feasibility of high-resolution spinal cord imaging at 7 T is demonstrated in in vivo images of volunteers. MATERIALS AND METHODS The RF phased array consists of 8 overlapping surface loop coils with a dimensio...

متن کامل

Magnetic Resonance Multi-view Inverse Imaging (MV InI) for Human Brain

Dynamic MRI usually uses echo-planar imaging (EPI) [1] to achieve high temporal resolution. In brain imaging, modern MRI systems can achieve 3D spatial encoding with the whole-brain coverage using multi-slice EPI with TR of 2 s. A significant amount of time of multi-slice EPI is spent over k-space traversal. Recently, we proposed the MR inverse imaging (InI) [2] to achieve the unprecedented tem...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 53 2  شماره 

صفحات  -

تاریخ انتشار 2008