The Fresnel effect of a defocused biprism on the fringes in inelastic holography.

نویسندگان

  • Jo Verbeeck
  • Giovanni Bertoni
  • Peter Schattschneider
چکیده

We present energy filtered holography experiments on a thin foil of Al. By propagating the reduced density matrix of the probe electron through the microscope, we quantitatively predict the fringe contrast as a function of energy loss. Fringe contrast simulations include the effect of Fresnel fringes created at the edges of the defocused biprism, the effect of partial coherence in combination with inelastic scattering, and the effect of a finite energy distribution of the incoming beam.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Phase-Related Techniques and Holographic Beam Shaping (inc. phase plates, DPC, vortices, electric and magnetic field imaging...) IM5.P136 Full-resolution high-contrast imaging of phase objects by gradient- flipping-assisted focal series reconstruction

When considering elastic electron scattering by thin samples in the transmission electron microscope (TEM) (e.g., by applying zero-loss energy filtering), samples that consist of light elements (e.g., almost all thin samples investigated by cryo TEM) affect mostly the phase of the probing electron wave function and produce very little absorption contrast. However, the phase component of the ima...

متن کامل

Axial resonance of periodic patterns by using a Fresnel biprism.

This paper proposes a method for the generation of high-contrast localized sinusoidal fringes with spatially noncoherent illumination and relatively high light throughput. The method, somehow similar to the classical Lau effect, is based on the use of a Fresnel biprism. It has some advantages over previous methods for the noncoherent production of interference fringes. One is the flexibility of...

متن کامل

Adapting a JEM-2100F for Magnetic Imaging by Lorentz TEM

Lorentz TEM enables to map quantitatively magnetic induction fields in the sample. A specifically designed objective lens, a coherent electron source, and a biprism filament can achieve magnetic imaging at the nanometer scale through off-axis electron holography experiments. However, this equipment is specialized and therefore not suited to many microscopy labs. In this article, we describe an ...

متن کامل

Electron Holography and Lorentz Microscopy of Magnetic Thin Films and Multilayers

A recently acquired 200-kV field emission gun transmission electron microscope equipped with a highmagnification Lorentz lens, an electrostatic biprism, and a slow-scan charge-coupled device (CCD) camera has been utilized for micromagnetic studies of ultrathin films and multilayers under relatively field-free conditions. For planview imaging of a thin Fe film and cross-sectional imaging of anis...

متن کامل

A holographic biprism as a perfect energy filter?

It has often been stated that a holographic biprism represents a near perfect energy filter and only elastically scattered electrons can participate in the interference fringes. This is based on the assumption that the reference wave does not contain inelastically scattered electrons. In this letter we show that this is not exactly true because of the delocalised inelastic interaction of the re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ultramicroscopy

دوره 108 3  شماره 

صفحات  -

تاریخ انتشار 2008